4. When positioning the machine, ensure that a uniform axial gap (y→0) is maintained around
the coupling.
5. Fix the machine to the foundation. The choice of fixing elements depends on the foundation
and is the plant operator's responsibility.
'
[
\
①
Plates placed under the motor for alignment
②
Laser alignment
Image 5-2
Schematic diagram: Aligning the machine to the driven machine
Table 5-2
Permissible deviations for aligning the machine with flexible coupling
Max. speed n
max
Max. parallel offset x
Max. angular offset y
n
max
≤ 1500 rpm
x
max
= 0.08 mm
y
max
= 0.08 mm / 100 mm ∅ D
1500 rpm <
n
max
≤ 3600 rpm
x
max
= 0.05 mm
y
max
= 0.05 mm / 100 mm ∅ D
Note
Machine expansion
When performing alignment, make allowance for the thermal expansion of the machine due
to rising temperature.
Assembling
5.3 Installing the machine
SIMOTICS DC 1GG6
48
Operating Instructions 02/2016
Summary of Contents for SIMOTICS DC 1GG6
Page 2: ...08 02 2016 10 27 V4 00 ...
Page 12: ...Table of contents SIMOTICS DC 1GG6 12 Operating Instructions 02 2016 ...
Page 14: ...Introduction 1 1 About these instructions SIMOTICS DC 1GG6 14 Operating Instructions 02 2016 ...
Page 70: ...Commissioning 7 8 Switch off SIMOTICS DC 1GG6 70 Operating Instructions 02 2016 ...
Page 82: ...Operation 8 9 Faults SIMOTICS DC 1GG6 82 Operating Instructions 02 2016 ...
Page 104: ...Maintenance 9 2 Repair SIMOTICS DC 1GG6 104 Operating Instructions 02 2016 ...
Page 138: ...Service and Support SIMOTICS DC 1GG6 138 Operating Instructions 02 2016 ...
Page 142: ...Quality documents SIMOTICS DC 1GG6 142 Operating Instructions 02 2016 ...
Page 153: ......