● Check the seals and sealing surfaces. Rectify the cause of the leak.
● Check the insulators, connectors and cable connections in the terminal box.
● Replace the damaged components if necessary.
WARNING
Short-circuit hazard
Short circuits, for example, can occur as a result of damaged components. This can result in
death, serious injury or material damage.
Replace damaged components.
Checking after subjection to heavy current
If the terminal box or the motor has been subjected to extremely heavy current, inspect the
electrical components.
9.1.12
Touch up any damaged paintwork
If the paint is damaged, it must be repaired in order to protect the unit against corrosion.
Note
Paint system
Contact the Service Center (Page 137) before you repair any paint damage. They will provide
you with more information about the correct paint system and methods of repairing paint
damage.
9.2
Repair
When carrying out any work on the machine, observe the general safety instructions
(Page 15) and the specifications contained in EN 50110‑1 regarding safe operation of electrical
equipment.
Note
If the motor has to be transported, please observe the information and instructions in the
"Transport" (Page 27) section.
Maintenance
9.2 Repair
SIMOTICS DC 1GG6
94
Operating Instructions 02/2016
Summary of Contents for SIMOTICS DC 1GG6
Page 2: ...08 02 2016 10 27 V4 00 ...
Page 12: ...Table of contents SIMOTICS DC 1GG6 12 Operating Instructions 02 2016 ...
Page 14: ...Introduction 1 1 About these instructions SIMOTICS DC 1GG6 14 Operating Instructions 02 2016 ...
Page 70: ...Commissioning 7 8 Switch off SIMOTICS DC 1GG6 70 Operating Instructions 02 2016 ...
Page 82: ...Operation 8 9 Faults SIMOTICS DC 1GG6 82 Operating Instructions 02 2016 ...
Page 104: ...Maintenance 9 2 Repair SIMOTICS DC 1GG6 104 Operating Instructions 02 2016 ...
Page 138: ...Service and Support SIMOTICS DC 1GG6 138 Operating Instructions 02 2016 ...
Page 142: ...Quality documents SIMOTICS DC 1GG6 142 Operating Instructions 02 2016 ...
Page 153: ......