Insulation system
The high-quality DURIGNIT® 2000 insulation system means that the motors are suitable for
use in both tropical humidity and industrial environments. You will find the insulation classes
in the following table.
Table 3-1
Insulation classes
Series
Insulation class
1GG5
155 (F)
1GH5
1HS5
1HQ5
1GG6, 1GG7
180 (H)
1GH6, 1GH7
1HS6, 1HS7
1HQ6, 1HQ7
Degree of protection
The machine has degree of protection IP23.
Ambient conditions
Unless otherwise specified, the rated powers apply for continuous operation at a coolant
temperature of ≤ 40 °C and an installation altitude of up to 1000 m above sea level. Please
note any data to the contrary on the rating plate. Operating conditions must comply with the
specifications on the rating plate.
Machine design
You will find regulations and standards for rating and testing this motor on the rating plate. The
machine design basically complies with the following standards. Please refer to the EC or EU
Declaration of Conformity for the versions of the harmonized standards referenced.
Table 3-2
Machine design
Characteristic
Standard
Ratings and operating performance
IEC/EN 60034‑1
Degree of protection
IEC/EN 60034‑5
Cooling
IEC/EN 60034‑6
Construction type
IEC/EN 60034‑7
Terminal markings and direction of rotation
IEC/EN 60034‑8
Noise emission
IEC/EN 60034‑9
Vibration severity grades
IEC/EN 60034‑14
Vibration limits
DIN ISO 10816-3
Description
SIMOTICS DC 1GG6
22
Operating Instructions 02/2016
Summary of Contents for SIMOTICS DC 1GG6
Page 2: ...08 02 2016 10 27 V4 00 ...
Page 12: ...Table of contents SIMOTICS DC 1GG6 12 Operating Instructions 02 2016 ...
Page 14: ...Introduction 1 1 About these instructions SIMOTICS DC 1GG6 14 Operating Instructions 02 2016 ...
Page 70: ...Commissioning 7 8 Switch off SIMOTICS DC 1GG6 70 Operating Instructions 02 2016 ...
Page 82: ...Operation 8 9 Faults SIMOTICS DC 1GG6 82 Operating Instructions 02 2016 ...
Page 104: ...Maintenance 9 2 Repair SIMOTICS DC 1GG6 104 Operating Instructions 02 2016 ...
Page 138: ...Service and Support SIMOTICS DC 1GG6 138 Operating Instructions 02 2016 ...
Page 142: ...Quality documents SIMOTICS DC 1GG6 142 Operating Instructions 02 2016 ...
Page 153: ......