Table 7-1
Minimum radial forces
Type 1G.6 16.
1G.6
1H.6 18.
1G.6
1H.6 20.
1G.6
1H.6 22.
1G.6
1H.6 25.
1G.6
1H.6 28.
1G.7
1H.7 35.
1G.7
1H.7 401
... 1H.
7 403
1G.7
1H.7 404
...
1H.7 405
1G.7
1H.7 45.
NU2
1.2 kN
4 kN
4.5 kN
6 kN
7.5 kN
9 kN
11 kN
14.5 kN
16.5 kN
14.5 kN
NU3
-
6 kN
7 kN
9 kN
10.5 kN
12.5 kN
-
-
-
-
7.5
Commissioning an external fan
Machines of shaft heights 250 and 280 are shipped with the air-outlet grille of the external fan
motor for connection to a 50 Hz supply already fitted. The cover sheet
①
for motors which
operate on 60 Hz is supplied as a motor accessory.
NOTICE
Operation on 60 Hz
In operation on a 60 Hz supply, the external fan motor can overheat or burn out. If you intend
to operate the external fan on a 60 Hz mains supply, then fit the cover sheet
①
with the
screws provided under the air-outlet grille before you commission the motor.
Commissioning
7.5 Commissioning an external fan
SIMOTICS DC 1GG6
66
Operating Instructions 02/2016
Summary of Contents for SIMOTICS DC 1GG6
Page 2: ...08 02 2016 10 27 V4 00 ...
Page 12: ...Table of contents SIMOTICS DC 1GG6 12 Operating Instructions 02 2016 ...
Page 14: ...Introduction 1 1 About these instructions SIMOTICS DC 1GG6 14 Operating Instructions 02 2016 ...
Page 70: ...Commissioning 7 8 Switch off SIMOTICS DC 1GG6 70 Operating Instructions 02 2016 ...
Page 82: ...Operation 8 9 Faults SIMOTICS DC 1GG6 82 Operating Instructions 02 2016 ...
Page 104: ...Maintenance 9 2 Repair SIMOTICS DC 1GG6 104 Operating Instructions 02 2016 ...
Page 138: ...Service and Support SIMOTICS DC 1GG6 138 Operating Instructions 02 2016 ...
Page 142: ...Quality documents SIMOTICS DC 1GG6 142 Operating Instructions 02 2016 ...
Page 153: ......