9.1.2
MTTR
Note
The operating conditions can vary greatly. For that reason, the following table only states
general intervals for inspections and service during fault-free operation.
Table 9-1
MTTR in fault-free operation
Measure
Interval
Time limit
Initial inspection
After 500 operating hours
After a half year at the
latest
Regreasing
After 1000 to 16 000 operating hours (depending on
bearings and operating mode)
After three years at
the latest
Cleaning
Dependent on local degree of pollution or when brush‐
es are replaced
Follow-up inspection 2,000 operating hours after the previous inspection
After a half year at the
latest
General inspection
Approximately every 16 000 operating hours
After two years at the
latest
9.1.3
Main inspection
The main inspection of the machine should be carried out after approximately 16000 operating
hours, but no later than after two years of operation.
DANGER
Rotating or live parts
Rotating or live parts are dangerous. Death, serious injury, or material damage can result if
the required covers are removed.
If no inspection windows are fitted and, as a result, the appropriate covers need to be removed
to allow inspection of the commutating performance, these covers may only be dismounted
by specially qualified personnel. This ensures that there is no contact with live or moving
parts. Wear safety goggles when working.
Checking the motor when in operation
● The relevant technical data are observed: power consumption, temperature of windings,
bearings, coolants, etc.
● There should be no oil, grease, or water leakages.
● The smooth running characteristics and motor running noise have not deteriorated.
● No impermissible brush sparking occurs in operation.
Maintenance
9.1 Inspection and maintenance
SIMOTICS DC 1GG6
86
Operating Instructions 02/2016
Summary of Contents for SIMOTICS DC 1GG6
Page 2: ...08 02 2016 10 27 V4 00 ...
Page 12: ...Table of contents SIMOTICS DC 1GG6 12 Operating Instructions 02 2016 ...
Page 14: ...Introduction 1 1 About these instructions SIMOTICS DC 1GG6 14 Operating Instructions 02 2016 ...
Page 70: ...Commissioning 7 8 Switch off SIMOTICS DC 1GG6 70 Operating Instructions 02 2016 ...
Page 82: ...Operation 8 9 Faults SIMOTICS DC 1GG6 82 Operating Instructions 02 2016 ...
Page 104: ...Maintenance 9 2 Repair SIMOTICS DC 1GG6 104 Operating Instructions 02 2016 ...
Page 138: ...Service and Support SIMOTICS DC 1GG6 138 Operating Instructions 02 2016 ...
Page 142: ...Quality documents SIMOTICS DC 1GG6 142 Operating Instructions 02 2016 ...
Page 153: ......