4. When positioning the machine, ensure that a uniform axial gap (y→0) is maintained around
the coupling.
5. Fix the machine to the foundation. The choice of fixing elements depends on the foundation
and is the plant operator's responsibility.
'
[
\
①
Plates placed under the motor for alignment
②
Laser alignment
Image 5-2
Schematic diagram: Aligning the machine to the driven machine
Table 5-2
Permissible deviations for aligning the machine with flexible coupling
Max. speed n
max
Max. parallel offset x
Max. angular offset y
n
max
≤ 1500 rpm
x
max
= 0.08 mm
y
max
= 0.08 mm / 100 mm ∅ D
1500 rpm <
n
max
≤ 3600 rpm
x
max
= 0.05 mm
y
max
= 0.05 mm / 100 mm ∅ D
Note
Machine expansion
When performing alignment, make allowance for the thermal expansion of the machine due
to rising temperature.
Assembling
5.3 Installing the machine
SIMOTICS DC 1GH5
46
Operating Instructions 02/2016
Summary of Contents for SIMOTICS DC 1GH5
Page 2: ...08 02 2016 10 31 V4 00 ...
Page 12: ...Introduction 1 1 About these instructions SIMOTICS DC 1GH5 12 Operating Instructions 02 2016 ...
Page 50: ...Assembling 5 3 Installing the machine SIMOTICS DC 1GH5 50 Operating Instructions 02 2016 ...
Page 76: ...Operation 8 9 Faults SIMOTICS DC 1GH5 76 Operating Instructions 02 2016 ...
Page 98: ...Maintenance 9 2 Repair SIMOTICS DC 1GH5 98 Operating Instructions 02 2016 ...
Page 110: ...Spare Parts 10 7 Speed sensor SIMOTICS DC 1GH5 110 Operating Instructions 02 2016 ...
Page 114: ...Service and Support SIMOTICS DC 1GH5 114 Operating Instructions 02 2016 ...
Page 118: ...Quality documents SIMOTICS DC 1GH5 118 Operating Instructions 02 2016 ...
Page 128: ...Index SIMOTICS DC 1GH5 128 Operating Instructions 02 2016 ...
Page 129: ......