Connecting
8.2 Electrical connection
SIMOTICS M-1FE2 built-in motors
116
Configuration Manual, 05/2021, A5E50494252B AB
8.2.1.3
Cable cross-section, cable outer diameter and cable variant for synchronous
versions
The values specified in the following table refer to the cable outlet of the motor.
Cable cross-sections (Cu) and outer diameter of the connecting cables
Motor type
Cable length l
l = 0.5 m
1)
l = 1.5 m
2)
Cable cross-section
per phase
3)
in mm
2
Outer cable diame-
ter
in mm
Cable cross-section
per phase
3)
in mm
2
Outer cable diame-
ter
in mm
16-pole built-in motors
1FE2182-8LN
☐☐
-
☐
CC1
2 x 6
2 x 5.0
2 x 10
2 x 6.8
1FE2182-8LH
☐☐
-
☐
CC1
2 x 16
2 x 9.1
2 x 16
2 x 9.1
1FE2183-8LN
☐☐
-
☐
CC1
2 x 6
2 x 5.0
2 x 10
2 x 6.8
1FE2183-8LH
☐☐
-
☐
CC1
2 x 25
2 x 10.5
2 x 25
2 x 10.5
1FE2184-8LN
☐☐
-
☐
CC1
2 x 10
2 x 6.8
2 x 16
2 x 9.1
1FE2184-8LK
☐☐
-
☐
CC1
2 x 25
2 x 10.5
2 x 35
2 x 11.9
1FE2184-8LH
☐☐
-
☐
CC1
2 x 25
2 x 10.5
2 x 35
2 x 11.9
1FE2185-8LN
☐☐
-
☐
CC1
2 x 16
2 x 9.1
2 x 16
2 x 9.1
1FE2185-8LL
☐☐
-
☐
CC1
2 x 25
2 x 10.5
2 x 35
2 x 11.9
1FE2185-8LH
☐☐
-
☐
CC1
2 x 35
2 x 11.9
2 x 50
2 x 14.6
1FE2186-8LN
☐☐
-
☐
CC1
2 x 16
2 x 9.1
2 x 25
2 x 10.5
1FE2186-8LM
☐☐
-
☐
CC1
2 x 25
2 x 10.5
2 x 35
2 x 11.9
1FE2186-8LH
☐☐
-
☐
CC1
2 x 50
2 x 14.6
2 x 50
2 x 14.6
1FE2187-8LN
☐☐
-
☐
CC1
2 x 25
2 x 10.5
2 x 35
2 x 11.9
1FE2187-8LH
☐☐
-
☐
CC1
2 x 50
2 x 14.6
--
--
1)
According to EN 46200 it can only be used in the motor spindle
2)
Notes on using cables are provided in VDE 0298, Part 3 and Part 4
3)
For large cable cross-sections, provide an elongated hole as bushing, where necessary.
You configure further connection cables appropriate for the rated current in accordance with
EN 60204-1 depending on the routing type and the ambient temperature.