Connecting
8.2 Electrical connection
SIMOTICS M-1FE2 built-in motors
Configuration Manual, 05/2021, A5E50494252B AB
141
Parameter
Designation
Total
Master
Slave
Index
Parameters(350, 0)
'Motor stator resistance, cold
0.0281
0.0562
0.0562
6)
Parameters(356, 0)
'Motor stator leakage inductance
0.723
1.446
1.446
6)
Parameters(392, 0)
'Current controller adaptation,
starting point KP adapted
469
234.5
234.5
6)
Parameters(393, 0)
'Current controller adaptation, P
gain adaptation
70
70
70
6)
Parameters(400, 0)
'Encoder type selection
9999
9999
9999
4)
Parameters(404, 0)
'Encoder configuration effective
&H109010
&H109010
&H109010
4)
Parameters(408, 0)
'Rotary encoder pulse number
256
256
256
4)
Parameters(425, 0)
'Encoder, rotary zero mark distance
256
256
256
4)
Parameters(431, 0)
'Commutation angle offset
83
83
0
1)
Parameters(604, 0)
'Mot_temp_mod 2 / KTY alarm
threshold
150
150
150
6)
Parameters(605, 0)
'Mot_temp_mod 41671 threshold
160
160
160
6)
Parameters(611, 0)
'I2t motor model thermal time
constant
240
240
240
6)
Parameters(612, 0)
'Mot_temp_mod activation
&H1
&H1
&H1
Parameters(640, 0)
'Current limit
469
234.5
234.5
5)
Parameters(643, 0)
'Overvoltage protection for syn-
chronous motors
0
1
1
Parameters(845, 0)
'BI: No coast down / coast down
(OFF2) signal source 2
1
722:10:01
722:10:01
VPM
Parameters(1082, 0)
'Maximum speed
2000
4200
4200
6)
Parameters(1441, 0)
'Speed actual value smoothing time
0.2
0.2
0.2
4)
Parameters(1460, 0)
'Speed controller P gain adaptation
speed lower
700
350
0
1) &
5)
Parameters(1520, 0)
'CO: Torque limit, upper/motoring
2006
1021
1021
5)
Parameters(1521, 0)
'CO: Torque limit, low-
er/regenerative
-2006
-1021
-1021
5)
Parameters(1530, 0)
'Power limit, motoring
210
107
107
5)
Parameters(1531, 0)
'Power limit, regenerative
-210
-107
-107
5)
Parameters(1612, 0)
'Current setpoint, open-loop con-
trol, encoderless
112.5
56.5
56.5
Parameters(1715, 0)
'Current controller P gain
2.0
6.0
6.0
Parameters(1752, 0)
'Motor model, changeover speed
operation with encoder
238
153
153
Parameters(1755, 0)
'Motor model changeover speed
encoderless operation
169
160
160
Parameters(1800, 0)
'Pulse frequency setpoint
4
4
4
Parameters(1815, 0)
Phase for PWM generation, subunit
&H1
&H1
&H1
3)
Parameters(1816, 0)
Phase for PWM generation, set
manually
0
0
0
3)
Parameters(1819, 0)
Phase for PWM generation
0
0
0
3)
Parameters(1980, 0)
'PolID procedure
1
1
1
Parameters(1981, 0)
'PolID maximum distance
30
30
30
2)
Parameters(1982, 0)
'PolID selection
1
1
1
Parameters(1993, 0)
'PolID motion-based current
30
30
30
2)
Parameters(1994, 0)
'PolID motion-based rise time
30
30
30
2)
Parameters(1995, 0)
'PolID motion-based gain
80
80
80
2)