Mechanical mounting
4.1 Installation
1PH808/1PH810 main motors
50
Operating Instructions, 04/2017, 610.48004.40f
●
Rotate the output elements by hand. If you hear any grinding noise, rectify the cause or
contact the manufacturer.
●
Eyebolts that have been screwed in must either be tightened or removed after installation.
●
Air-cooled motors must be installed in such a way that the cooling air can flow in and out
without any obstruction and that the minimum distance s is maintained between the air
inlet and discharge openings and adjacent components (see "Minimum distance" diagram
in "Cooling" section). It is not permissible that the hot air is drawn-in again.
Note
Covers attached to the motor
•
You must remount the covers for air-cooled motors, which were removed to allow the
motors to be secured, before commissioning.
Figure 4-1
Cover for foot mounting
①
at NDE (example)