Connection
5.2 Electrical connection
1PH808/1PH810 main motors
88
Operating Instructions, 04/2017, 610.48004.40f
Current-carrying capacity for power and signal cables
The current-carrying capacity of PVC/PUR-insulated copper cables is specified in
EN 60204-1.
5.2.2
Circuit diagram
The circuit diagram contains information about wiring and connecting the motor winding. The
circuit diagram can be found on the lid of the terminal box.
Figure 5-1
Circuit diagram
NOTICE
Cable damage caused by inappropriately changing the cable outlet direction
You will damage connecting cables if you inappropriately change the cable outlet direction.
•
The direction of the cable outlet must not be changed as this invalidates warranty
claims.
5.2.3
Terminal box
●
Assign the terminals in the terminal box as shown in the diagrams "Terminal box: 3-pole"
and "Terminal box: 6-pole".
●
Connect the protective conductor.
●
Use cable lugs to DIN 46234.
●
Do not remove the insulation strips.
●
Screw the terminal box cover on again (tightening torque 5 Nm).