Description
2.3 Derating factors
SIMOTICS S-1FG1 servo geared motor
24
Operating Instructions, 07/2019, A5E47360747B AA
2.2.4
Address of CE-authorized manufacturer
The CE Declaration of Conformity is held on file available to the competent authorities at the
following address:
Siemens AG
Digital Industries
Motion Control
Industriestraße 1
DE-97615 Bad Neustadt a. d. Saale
Germany
2.3
Derating factors
Under conditions other than those specified above (ambient temperature > 40 °C or
installation altitude > 1000 m above sea level), the permissible torques/powers are shown in
the following table.
Ambient temperatures and installation altitudes are rounded off to 5 °C or 500 m
respectively.
Table 2- 2
Power derating depending on the installation altitude and the ambient temperature
Installation altitude
above sea level in m
Ambient temperature in °C
30
35
40
45
50
55
1000
1.05
1.02
1.00
0.97
0.95
0.92
1500
1.02
1.00
0.97
0.95
0.92
0.89
2000
1.00
0.97
0.95
0.92
0.89
0.87
2500
0.97
0.95
0.92
0.89
0.87
0.84
3000
0.95
0.92
0.89
0.87
0.84
0.81
3500
0.92
0.89
0.87
0.84
0.81
0.77
4000
0.89
0.87
0.84
0.81
0.77
0.74
The factors refer to the static torque M
0
. You shift the S1 characteristic curve in parallel.