Connecting
4.3 Control/status interface - X8
SINAMICS V90, SIMOTICS S-1FL6
Operating Instructions, 04/2019, A5E36037884-007
129
No.
Name
Descriptions
Control mode
PTI
IPos
S
T
Fast
PTI
8
MBR
Motor holding brake
•
1: the motor holding brake is engaged.
•
0: the motor holding brake is released.
Note: MBR is only a status signal because the con-
trol and the power supply of the motor holding brake
are realized with separate terminals.
✓
✓
✓
✓
✓
9
OLL
Overload level reached
•
1: the motor has reached the parameterizable
output overload level (p29080 in % of the rated
torque; default: 100%; max: 300%).
•
0: the motor has not reached the overload level.
✓
✓
✓
✓
✓
10 WARNING
1
Warning 1 condition satisfied
•
1: the parameterizable warning 1 condition has
been satisfied.
•
0: the parameterizable warning 1 condition has
not been satisfied.
See the note below on warning condition settings.
✓
✓
✓
✓
✓
11 WARNING
2
Warning 2 condition satisfied
•
1: the parameterizable warning 2 condition has
been satisfied.
•
0: the parameterizable warning 2 condition has
not been satisfied.
See the note below on warning condition settings.
✓
✓
✓
✓
✓
12
REFOK Referenced
•
1: referenced.
•
0: not referenced.
X
✓
X
X
X
13
CM_STA Current control mode
•
1: the second mode in five compound control
modes (PTI/S, IPos/S, PTI/T, IPos/T, S/T).
•
0: the first mode in five compound control modes
or four basic modes (PTI, IPos, S, T).
✓
✓
✓
✓
X