Parameters
10.2 Parameter list
SINAMICS V90, SIMOTICS S-1FL6
Operating Instructions, 04/2019, A5E36037884-007
371
Par. No.
Name
Min
Max
Factory
Setting
Unit Data
type
Effective
Can be
changed
p29306[0..
.9]
Digital input 6 assignment 0
28
[0...1] 6;
[2...3]
13; [9]
19
-
I16
IM
T
Description: Defines the function of digital input signal DI6
Index:
•
[0]: DI6 for the control mode 0
•
[1]: DI6 for the control
mode 1
•
[2]: DI6 for the control mode 2
•
[3]: DI6 for the control mode 3
•
[4...8]: Reserved
•
[9]: DI6 for the control mode 9
p29307[0..
.9]
Digital input 7 assignment 0
28
[0] 7; [1]
21; [2]
15; [3]
18; [9] 7
-
I16
IM
T
Description: Defines the function of digital input signal DI7
Index:
•
[0]: DI7 for the control mode 0
•
[1]: DI7 for the control mode 1
•
[2]: DI7 for the control mode 2
•
[3]: DI7 for the control mode 3
•
[4...8]: Reserved
•
[9]: DI7 for the control mode 9
p29308[0..
.9]
Digital input 8 assignment 0
28
[0] 10;
[1] 22;
[2] 16;
[3] 19;
[9] 10
-
I16
IM
T
Description: Defines the function of digital input signal DI8
Index:
•
[0]: DI8 for the control mode 0
•
[1]: DI8 for the control mode 1
•
[2]: DI8 for the control mode 2
•
[3]: DI8 for the control mode 3
•
[4...8]: Reserved
•
[9]: DI8 for the control mode 9