Parameters
10.2 Parameter list
SINAMICS V90, SIMOTICS S-1FL6
372
Operating Instructions, 04/2019, A5E36037884-007
Par. No.
Name
Min
Max
Factory
Setting
Unit Data
type
Effective
Can be
changed
p29330
Digital output 1 assign-
ment
1
15
1
-
I16
IM
T
Description: Defines the function of digital output signal DO1
•
1: RDY
•
2: FAULT
•
3: INP
•
4: ZSP
•
5: SPDR
•
6: TLR
•
7: SPLR
•
8: MBR
•
9: OLL
•
10: WARNING1
•
11: WARNING2
•
12: REFOK
•
13: CM_STA
•
14: RDY_ON
•
15: STO_EP
p29331
Digital output 2 assign-
ment
1
15
2
-
I16
IM
T
Description: Defines the function of digital output signal DO2
p29332
Digital output 3 assign-
ment
1
15
3
-
I16
IM
T
Description: Defines the function of digital output signal DO3
p29333
Digital output 4 assign-
ment
1
15
5
-
I16
IM
T
Description: Defines the function of digital output signal DO4
p29334
Digital output 5 assign-
ment
1
15
6
-
I16
IM
T
Description: Defines the function of digital output signal DO5
p29335
Digital output 6 assign-
ment
1
15
8
-
I16
IM
T
Description: Defines the function of digital output signal DO6
p29340
Warning 1 assigned for
digital output
1
6
1
-
U16
IM
T
Description: Defines conditions for WRN1.
•
1: Motor overload protection warning: 85% of overload threshold has been reached.
•
2: Holding brake power overload warning: threshold p29005 has been reached.
•
3: Fan warning: fan has stopped for more than 1 s.
•
4: Encoder warning
•
5: Motor overtemperature warning: 85% of overtemperature threshold has been reached.
•
6: Capacitor service life warning: The capacitor has reached its expiry, so replace it.