General information
2.2 Device combination
SINAMICS V90, SIMOTICS S-1FL6
Operating Instructions, 04/2019, A5E36037884-007
37
Note
You can select a SINAMICS V90 servo drive for all the SIMOTICS S-1FL6 servo motors
whose rated power values are equal to or smaller than that specified as matching with this
servo drive in the table above.
When the rated power of the connected motor is smaller than that of the drive, make sure
that the actual load of the motor is within the overload capacity of the drive. For more
information, see Section "300% overload capacity (Page 213)".
For this kind of application, you need to consult with the Siemens service before operating.
Note
Before your commissioning, check the motor ID in the drive (p29000) and make sure that the
value is that specified on the rating plate of the connected motor, especially when the drive is
working with a motor whose rated power value is lower than that of this drive.