Electrical connection
8.3 System integration
1FW3 complete torque motors
302
Configuration Manual, 08/2020, A5E46027705B AA
8.3.1
Connecting to the converter
1
Terminal Module
8
Motors without DRIVE-CLiQ interface
2
Control Unit
9
Motors with DRIVE-CLiQ interface
3
Operator control unit
A
MOTION-CONNECT power cable
4
Smart Line or Active Line Module
B
MOTION-CONNECT signal cable
5
Double Motor Module
C DRIVE-CLiQ signal cable
6
Motor Module
D MOTION-CONNECT DRIVE-CLiQ signal
cable
7
Sensor Module
Figure 8-3
SINAMICS S120 system overview
The complete torque motors can be operated in 4 quadrants. They can be connected to a
controlled or uncontrolled infeed unit.
WARNING
Uncontrolled motor motion as a result of incorrect adjustment
The encoders are adjusted in the factory for SIEMENS drive converters. Another encoder
adjustment may be required when operating the motor with a third-party converter.
Incorrect adjustment of the encoder regarding motor EMF can lead to uncontrolled motion
which can cause injury and material damage.
•
Only replace an encoder and adjust it if you are appropriately qualified to do so.
•
When a belt-driven encoder is replaced, adjust the position of the encoder system with
respect to the motor EMF.
•
You must re-reference the system when replacing an absolute encoder.
Note
Replacing a coaxially mounted encoder
When replacing a coaxially mounted encoder, you do not have to adjust the encoder system.
The position with respect to the motor EMF is ensured using mechanical components.