Mechanical properties
3.1 Cooling
1FW3 complete torque motors
Configuration Manual, 08/2020, A5E46027705B AA
43
Note
Independence of derating factors
For water cooling, the derating factors are independent of the installation altitude.
•
The ambient conditions change with increasing installation altitude. As a consequence,
ensure that the required cooling water inlet temperature is available for the cooling
system.
Cooling powers to be dissipated and the cooling flow rate
The values specified in the table "Cooling power to be dissipated" refer to a cooling-water
temperature of +30 °C and S1 duty.
The cooling power to be dissipated specified in the table refers to the highest power loss to
be dissipated for the particular shaft height for a maximum temperature difference between
cooling water intake/cooling water discharge of 10 K.
Table 3- 4
Cooling power to be dissipated
Motor type
Cooling power to be dissipated
at
n
N
in kW
Pressure loss
Δ
p
in bar
Cooling flow rate
V
in l/min
SH 150 Standard
1FW3150-1
1.4
0.1
2.0
1FW3152-1
1.6
0.1
3.0
1FW3154-1
2.3
0.2
4.5
1FW3155-1
2.7
0.1
5.5
1FW3156-1
3.4
0.2
7.0
SH 200 Standard
1FW3201-1
1.7
0.1
3.0
1FW3202-1
2.3
0.2
4.0
1FW3203-1
3.4
0.1
5.0
1FW3204-1
3.9
0.1
6.0
1FW3206-1
5.5
0.3
8.0
1FW3208-1
8.4
0.6
10.0
SH 200 High Speed
1FW3201-3
2.9
0.2
3.5
1FW3202-3
4.2
0.4
5.0
1FW3203-3
5.4
0.1
6.5
1FW3204-3
6.7
0.2
8.0
1FW3206-3
8.8
0.5
10.5
1FW3208-3
10.9
1.0
13.0
SH 280 Standard
1FW3281-2
7.9
0.5
11.0
1FW3283-2
9.0
0.7
13.0
1FW3285-2
12.8
0.7
16.0
1FW3287-2
15.7
0.8
20.0