Electrical connection
8.3 System integration
1FW3 complete torque motors
306
Configuration Manual, 08/2020, A5E46027705B AA
Table 8- 4
Cable cross-sections (Cu) and outer diameter of the connecting cables in the standard version
Shaft
height
Option
5)
Rated current (I
N
)
Terminal
box type
Terminal
bolt diam.
(mm)
Thread for
cable entry
Cable entry
max. diam. /
width A/F
(mm)
Max. con-
ductor cross-
section
1)
(mm
2
)
Conductor
diam.
(mm)
150
w/o
I
N
≤
50 A
GK 230
5
2 x M32 x 1.5
46 / 40
2 x 16
11 - 24
w/o
50 A < I
N
< 105 A
GK 420
10
2 x M40 x 1.5
60 / 55
2 x 35
19 - 31
w/o
105 A < I
N
< 260 A
GK 630
10
2 x M50 x 1.5
68 / 60
2 x 50
27 - 38
M02
1)
I
N
≤
260 A
GK 603
5 / 10
2 x M63 x 1.5
81 / 75
2 x 50
11 - 38
200
w/o
I
N
≤
50 A
GK 230
5
2 x M32 x 1.5
46 / 40
2 x 16
11 - 24
w/o
50 A < I
N
< 105 A
GK 420
10
2 x M40 x 1.5
60 / 55
2 x 35
19 - 31
w/o
4)
105 A < I
N
≤
260 A
GK 630
10
2 x M50 x 1.5
68 / 60
2 x 50
27 – 38
M02
1)
I
N
≤
260 A
GK 603
5 / 10
2 x M63 x 1.5
81 / 75
2 x 50
11 – 38
P01
2)
260 A < I
N
≤
450 A 1XB7-700
12
3 x M63 x 1.5
92 / 81
3 x 95
39 – 52
w/o
260 A < I
N
≤
450 A 1XB7-700
12
3 x M75 x 1.5
92 / 81
3 x 120
41 – 56
280
P01
2)
I
N
≤
450 A
1XB7-700
12
3 x M63 x 1.5
92 / 81
3 x 95
39 – 52
w/o
I
N
≤
450 A
1XB7-700
12
3 x M75 x 1.5
92 / 81
3 x 120
41 - 56
P04
3)
450 A < I
N
≤
710 A 1XB7-712
16
4 x M63 x 1.5
92 / 81
4 x 95
39 - 52
w/o
450 A < I
N
≤
830 A 1XB7-712
16
4 x M75 x 1.5
105 / 95
4 x 120
41 - 56
1)
Option M02: Terminal box GK 603 with removable front plate
2)
Option P01: Cable entry plate 3 x M63 x 1.5 for terminal box 1XB7-700
3)
Option P04: Cable entry plate 4 x M63 x 1.5 for terminal box 1XB7-712
4)
1FW3206-3
❑
P supplied as standard with 1XB7-700. Terminal box GK 630 is possible on request.
5)
You must order the options separately.
Note
MOTION-CONNECT 500 power cables are available up to a cross-section of 120 mm² and
MOTION-CONNECT 800PLUS up to 50 mm
2
.
The listed cables are UL and/or CSA approved.
The approvals can be taken from the current catalog in Chapter "MOTION-CONNECT
connection system".
8.3.3
Signal connection/motor protection
DRIVE-CLiQ is the preferred method for connecting the encoder systems to SINAMICS.
Motors with a DRIVE-CLiQ interface can be ordered for this purpose. Motors with a DRIVE-
CLiQ interface can be directly connected to the associated motor module via the available
MOTION-CONNECT DRIVE-CLiQ cables. The MOTION-CONNECT DRIVE-CLiQ cable is
connected to the motor in degree of protection IP67. The DRIVE-CLiQ interface supplies
power to the motor encoder via the integrated 24 V DC supply and transfers the motor
encoder and temperature signals and the electronic type plate data, e.g. a unique
identification number, rating data (voltage, current, torque) to the control unit. The MOTION-
CONNECT DRIVE-CLiQ cable is used universally for connecting the various encoder types.
These motors simplify commissioning and diagnostics, as the motor and encoder type are
identified automatically.
Summary of Contents for SIMOTICS T-1FW3
Page 1: ...1FW3 complete torque motors ...
Page 2: ......
Page 8: ...Introduction 1FW3 complete torque motors 6 Configuration Manual 08 2020 A5E46027705B AA ...
Page 12: ...Table of contents 1FW3 complete torque motors 10 Configuration Manual 08 2020 A5E46027705B AA ...
Page 353: ......
Page 354: ......