Connection
5.5 Signal connection
Naturally cooled 1FW6 built-in torque motors
74
Operating Instructions, 07/2017, 6SN1197-0AF02-0BP2
PTC elements must be evaluated for thermal motor protection. On this topic, refer to the
Configuration Manual "Naturally cooled SIMOTICS 1FW6 built-in torque motors".
Table 5- 6
Conductor assignment for Temp-S and Temp-F temperature sensor cables
Core assignment for motors with signal cable
without connector
Sensor contact for 1FW6
white
-1R2: -KTY or Pt1000
brown
+1R1: +KTY or Pt1000
green
1TP1: PTC 130 °C
yellow
1TP2: PTC 130 °C
gray
-
pink
-
green/yellow
PE