Commissioning
8-123
E
Siemens AG, 2003 All rights reserved
SIMOTION C230-2, 04.2003 Edition
8.7
Resetting the C230-2 to the default setting as delivered
Overview
You can reset the C230-2 to the as delivered state (default setting) via operations
on the mode selector.
The following data is deleted:
S
Configuration data
S
Programs
S
Parameterizations
S
Technology packages
S
Retain variables
Retain variables are variables that are defined as “Non-volatile variables” in the
user program using the key word “Retain”.
S
Diagnostics buffer
S
Clock
The following data is retained:
S
SIMOTION Kernel
The following data is reset:
S
Baud rate = 1.5 Mbit/s
S
PROFIBUS address for the interfaces X8 = 2 and X9 = 2
S
IP address = 169.254.11.22, subnet dialog box = 255.255.0.0 and
router address = 169.254.11.22
Operations on the mode selector
Proceed as follows:
1. Switch off the power supply for the C230-2.
2. Remove the Micro Memory Card from the C230-2.
3. Turn the key on the mode selector to the MRES position. Hold the key in this
position and switch on the power supply for the C230-2. When the “STOPU”
LED flickers, turn the key to the STOP position again.
Summary of Contents for SIMOTION C230-2
Page 16: ...Product Overview 1 16 E Siemens AG 2003 All rights reserved SIMOTION C230 2 04 2003 Edition ...
Page 70: ...Installation 4 70 E Siemens AG 2003 All rights reserved SIMOTION C230 2 04 2003 Edition ...
Page 124: ...Commissioning 8 124 E Siemens AG 2003 All rights reserved SIMOTION C230 2 04 2003 Edition ...
Page 130: ...Maintenance 9 130 E Siemens AG 2003 All rights reserved SIMOTION C230 2 04 2003 Edition ...