Wiring
6-91
E
Siemens AG, 2003 All rights reserved
SIMOTION C230-2, 04.2003 Edition
Proceed as follows:
1. Wire the free cable end of the connecting cable to the terminals on the drive
unit. (The terminal markings on the cable ends indicate the corresponding ter-
minals for SIMODRIVE devices).
2. Open the front cover of the C230-2 and insert the Sub-D socket (50-pin) into
the X2 connector.
3. Lock the connector using the finger screws. Close the front cover.
Connecting cable
The connecting cable is a pre-assembled cable for four axes with an analog inter-
face, terminal designation for SIMODRIVE drives.
The connecting cable is available in a choice of lengths.
See
Catalog NC Z or Catalog NC 60 or Catalog ST 70.
Connection diagram
14
47
¬
SIMOTION C230-2
SIMODRIVE 611-A
Shield on housing
¬
¬
¬
Wires twisted and shielded in pairs
Connector sleeves
with designations
Shield
¬
¬
¬
¬
¬
Axis 2
Axis 3
Axis 4
9
65
14
56
9
65
14
56
9
65
56
14
9
65
14
56
15
48
1
34
2
35
16
49
3
36
17
50
37
4
REFPOT4
SETP4
CTREN4.1
CTREN4.2
REFPOT3
SETP3
CTREN3.1
CTREN3.2
REFPOT2
SETP2
CTREN2.1
CTREN2.2
REFPOT1
SETP1
CTREN1.1
CTREN1.2
24 V
Input enable
+
–
Fig. 6-7
Connection diagram of C230-2 to SIMODRIVE 611-A
Summary of Contents for SIMOTION C230-2
Page 16: ...Product Overview 1 16 E Siemens AG 2003 All rights reserved SIMOTION C230 2 04 2003 Edition ...
Page 70: ...Installation 4 70 E Siemens AG 2003 All rights reserved SIMOTION C230 2 04 2003 Edition ...
Page 124: ...Commissioning 8 124 E Siemens AG 2003 All rights reserved SIMOTION C230 2 04 2003 Edition ...
Page 130: ...Maintenance 9 130 E Siemens AG 2003 All rights reserved SIMOTION C230 2 04 2003 Edition ...