Wiring
6-94
E
Siemens AG, 2003 All rights reserved
SIMOTION C230-2, 04.2003 Edition
6.2.3
Connecting encoders
Connecting the connecting cable
Note the following:
Note
Only use shielded cables; the shield must be connected to the metallic or meta-
lized connector housing.
The pre-assembled cable available as an accessory provides the best possible
immunity to interference and adequately dimensioned cross sections for the power
supply to the encoders.
C230-2
Connecting cable
Axis 1...4
X2
X3
X4
X6
X5
X1
SIEMENS
The following encoders can be connected:
S
Incremental encoder with RS422
S
ROD 320 (built-in encoder in 1FT5)
S
SSI absolute encoder
S
Linear position encoder with EXE
S
SIMODRIVE 611 analog closed-loop control module 1FK6 motors with resolver
S
SIMODRIVE 611 universal with incremental shaft encoder interface
C230-2
X7
Fig. 6-9
Encoder connections