Maintenance
9-128
E
Siemens AG, 2003 All rights reserved
SIMOTION C230-2, 04.2003 Edition
Installing a new module
Proceed as follows:
1. Remove the upper part of the front connector keying from the new module.
2. Insert a module of the same type, swing it down and screw it in tightly.
3. Plug in the front connector and move it into operating position (tighten mounting
screw). The keying fitting adjusts so that the front connector only fits this mod-
ule type.
4. Connect the Sub-D connectors.
5. Connect the load power supply on the terminal strip.
6. Close the front covers and insert the labeling strip.
The control is now ready for operation again and can be commissioned.
7. Switch on the power supply.