Standards and Approvals
A-137
E
Siemens AG, 2003 All rights reserved
SIMOTION C230-2, 04.2003 Edition
Reduction in vibration
If the C230-2 is subjected to severe shocks or vibration, take appropriate mea-
sures to reduce the acceleration or amplitude.
We recommend installation on dampening material (e.g. rubber-metal vibration
dampers).
Testing mechanical environmental conditions
The following table provides information on the type and extent of tests of mechan-
ical environmental conditions.
Test for ...
Test standard
Remarks
Vibration
Vibration test to
IEC 68 Part 2-6 (sinu-
soidal)
Severity 12
Vibration type: Frequency sweeps with a rate of
change of 1 octave per minute.
10 Hz
v
f
v
58 Hz, constant amplitude
0.075 mm
58 Hz
v
f
v
500 Hz, constant acceleration 1 g
Period of oscillation: 10 frequency sweeps per
axis in all three perpendicular axes
Shock
Shock test to
IEC 68 Part 2-27
Type of shock: Semi-sinusoidal
Force of shock: 15 g peak value,
11 ms duration
Direction of shock: 3 shocks per +/– direction in
all three perpendicular axes
Summary of Contents for SIMOTION C230-2
Page 16: ...Product Overview 1 16 E Siemens AG 2003 All rights reserved SIMOTION C230 2 04 2003 Edition ...
Page 70: ...Installation 4 70 E Siemens AG 2003 All rights reserved SIMOTION C230 2 04 2003 Edition ...
Page 124: ...Commissioning 8 124 E Siemens AG 2003 All rights reserved SIMOTION C230 2 04 2003 Edition ...
Page 130: ...Maintenance 9 130 E Siemens AG 2003 All rights reserved SIMOTION C230 2 04 2003 Edition ...