Device Data
3-45
E
Siemens AG, 2003 All rights reserved
SIMOTION C230-2, 04.2003 Edition
Digital outputs (onboard)
Eight digital outputs (Q0...Q7) are provided on the C230-2.
These fast outputs (onboard) correspond to the Standard IEC 1131-2/DIN EN
61131-2 (24 V-P-switching). They can be used as freely addressable process out-
puts or as “fast output cams” (path switching signals). Allocation is in the hardware
configuration.
When used as cams, the outputs are output with an accuracy of approx. 140
µ
s.
When used as process outputs, the outputs are output with an accuracy of approx.
125
µ
s.
READY output
The ready signal (RDY.1, RDY.2) is an isolated contact assembly (make contact).
The contact can be used for the safe shutdown of parts of the system, for exam-
ple, through integration in the EMERGENCY STOP circuit.
The following table describes the states of the enables and outputs in the corre-
sponding C230-2 operating states with an open or closed READY contact.
Status of
READY contact
C230-2 ...
Status of enable signals and out-
puts ...
Open
S
During ramp-up
S
During overall reset
S
With fault condition
S
In STOP mode
S
In STOPU mode
S
Controller enable deactivated
S
Analog outputs at 0 V
S
Digital outputs deactivated
Closed
S
In RUN
Enable signals and outputs con-
trolled by user program and technol-
ogy
Summary of Contents for SIMOTION C230-2
Page 16: ...Product Overview 1 16 E Siemens AG 2003 All rights reserved SIMOTION C230 2 04 2003 Edition ...
Page 70: ...Installation 4 70 E Siemens AG 2003 All rights reserved SIMOTION C230 2 04 2003 Edition ...
Page 124: ...Commissioning 8 124 E Siemens AG 2003 All rights reserved SIMOTION C230 2 04 2003 Edition ...
Page 130: ...Maintenance 9 130 E Siemens AG 2003 All rights reserved SIMOTION C230 2 04 2003 Edition ...