Device Data
3-51
E
Siemens AG, 2003 All rights reserved
SIMOTION C230-2, 04.2003 Edition
3.4
Technical data
Memory for user data
S
Area for the technology packages and user data (programs, configuration data,
parameterization)
S
Retentive data area
S
Diagnostics buffer (100 messages)
S
Micro Memory Card
System cycle clocks
Basic cycle clock (isochronous bus cycle not activated)
1.5 to 10 ms
DP cycle clock (isochronous bus cycle activated)
1.5 to 10 ms
Position control cycle clock
≥
1 ms
Interpolator cycle clock (IPO cycle clock)
≥
1 ms
A modification can be made in the Engineering System.
See SIMOTION SCOUT operating instructions for setting the system cycle clocks.
Address areas
Input address area, total
1 Kbyte
Output address area, total
1 Kbyte
Process image inputs
64 bytes
Process image outputs
64 bytes
Connection values
Supply voltage
24 VDC (permissible range: 20.4...28.8 V)
Power consumption from 24 V
S
typically 0.9 A (inputs/outputs open)
S
typically 1.2 A (with 4 encoders, 5 V)
S
typically 1.9 A (with 4 encoders, 24 V)
Power loss
15 W
Starting current
8 A
Encoder supply 5 V max. output current
1.2 A
Encoder supply 24 V max. output current
1.2 A
Summary of Contents for SIMOTION C230-2
Page 16: ...Product Overview 1 16 E Siemens AG 2003 All rights reserved SIMOTION C230 2 04 2003 Edition ...
Page 70: ...Installation 4 70 E Siemens AG 2003 All rights reserved SIMOTION C230 2 04 2003 Edition ...
Page 124: ...Commissioning 8 124 E Siemens AG 2003 All rights reserved SIMOTION C230 2 04 2003 Edition ...
Page 130: ...Maintenance 9 130 E Siemens AG 2003 All rights reserved SIMOTION C230 2 04 2003 Edition ...