● A monitoring measuring input can only be interconnected with one measuring input on the
input side.
● A monitoring measuring input has no interconnection on the output side.
● An axis TO or an external encoder can be interconnected with more than one measuring
input, including a mixture of measuring inputs and monitoring measuring inputs. Depending
on the hardware (see Chapter More than one measuring input on one axis/encoder (as of
V3.2)), more than one measuring input may be active simultaneously.
● Local measuring inputs (onboard I/O from SINAMICS and C2xx) cannot be used for the
measuring input. Only global measuring inputs can be used (see Hardware for measuring
● Only single-stage interconnections are possible.
Note
You will find more information on interconnections in the
SIMOTION Runtime Basic
Functions function manual.
$[LVRU
([WHUQDOHQFRGHU
0HDVXULQJ,QSXW72
0HDVXULQJ
LQSXW
$[LVRU
([WHUQDOHQFRGHU
0HDVXULQJ,QSXW72
0HDVXULQJ
LQSXW
/LVWHQLQJ
0HDVXULQJ,QSXW72
$[LVRU
([WHUQDOHQFRGHU
2XWSXWVLGH
PHDVXULQJLQSXW
LQWHUFRQQHFWLRQ
,QSXWVLGHPHDVXU
LQJLQSXWLQWHUFRQ
QHFWLRQ
6WDQGDUG
PHDVXULQJLQSXWLQWHUFRQ
QHFWLRQ
([SDQVLRQWROLVWHQLQJPHDVXULQJLQSXW
Figure 5-6
Interconnecting monitoring measuring inputs
See also
Several Measuring Input TOs on one axis/encoder (as of V3.2) (Page 135)
Measuring input types - local and global measuring inputs (Page 131)
Measuring Input TO - Part III
5.2 Fundamentals of Measuring Input technology object
Output Cams and Measuring Inputs
138