● Axis reference position: 20
● Activation mode: Cyclic
● Axis reference position: 20
● Track length: 130
The following applies:
● A change of axis reference position causes a change in the cyclic and non-cyclic mode.
The cam track is offset once.
● A track length change only affects the cyclic mode and causes an offset in the cam track
cycle.
Display of given cam track with modified start/stop mode
● Start mode: Effective immediately
● Position of axis on which _enableCamTrack occurs: 40
● Position at which _disableCamTrack occurs: 170
● Activation mode: Cyclic
● Start mode: Immediate for inactive output cam track output
● Position of axis on which _enableCamTrack occurs: 40
4.2.8.2
Advanced mappings with shifted output cam positions
The following chapter presents examples of a cam track with shifted single cams, i.e. when
they are mapped onto the axis, single cams are shifted to another position if they are defined
outside the track length.
Cam Track TO - Part II
4.2 TO Cam Track basics
Output Cams and Measuring Inputs
Function Manual, 04/2014
97