Source for the ON/OFF1 command (control word 1, bit 0):
P554 (=22A Hex)
Change parameter value of index 1 to the value 3100.
Parameter value (PWE)
3rd word
(PWE1)
Byte 5
Byte 4
Bit No.:
15
8 7
0
HEX value
3
1
0
0
4th word
(PWE2)
Byte 7
Byte 6
Bit No.:
31
24 23
16
HEX value
0
0
0
0
Bits 8 to 15:
Bits 16 to 31:
Parameter value in the case of 16-bit parameter or low
component in the case of 32-bit parameter
Value = 0 in the case of 16-bit parameter or high component in
the case of 32-bit parameter