Parameter
Description
Data
Read/write
r186
MeasValStore
186
Index 1: measurement
Index 2: measurement with offset
Dec.Plc.: 0
Unit: -
Indices: 2
Type: I4
Menus:
- Parameter menu
+ Control/gating unit
+ Position control
- Upread/free access
P187*
TimeSlot PosSetp
187
Parameter for entering the time slot in which the wired
connectors of Src Position Setpoint P190, Src PRE
PosReg P209, Src PosCorr'nV P174 and the DSP control
word (contains technology control word e.g. POV, NOV)
are generated.
(Analogous to U060 Sample&Hold element
parameter for entering the slower time slot)
Init: 2
Min: 2
Max: 10
Unit: -
Indices: -
Type: O2
Menus:
- Parameter menu
+ Free blocks
- Upread/free access
Changeable in:
- Ready to switch on
P188*
Offset RotorPos
188
This parameter enables an offset between the mechanical
rotor position and the rotor position used for position
sensing to be set. The offset is used during referencing if
the rotor zero position falls together with the negative
edge of the rough pulse.
Init: 0,000
Min: -200,000
Max: 199,999
Unit: %
Indices: -
Type: I4
Menus:
- Parameter menu
- Upread/free access
Changeable in:
- Ready to switch on
- Operation enabled
r189
RotorPosBeroEdge
189
The parameter outputs the measured rotor position at the
negative flank of the rough pulse.
Dec.Plc.: 3
Unit: -
Indices: -
Type: I4
Menus:
- Parameter menu
+ Control/gating unit
+ Position control
- Upread/free access
P190*
S.Pos Setp
190
BICO parameter for selecting the connector from which
the setpoint for the position controller is to be read in.
index1: 310
Unit: -
Indices: 2
,BDS
Type: L2 ,K
,K
Menus:
- Parameter menu
+ Control/gating unit
+ Position control
- Upread/free access
Changeable in:
- Ready to switch on
- Operation enabled
P191*
Smooth Pos Set
191
Function parameter for entering the smoothing time
constant for the position setpoint.
index1: 0,0
Min: 0,0
Max: 1000,0
Unit: ms
Indices: 4
,FDS
Type: O2
Menus:
- Parameter menu
+ Control/gating unit
+ Position control
- Upread/free access
Changeable in:
- Ready to switch on
- Operation enabled
P192*
S.SetV PosSet
192
BICO parameter for selecting the connector from which
the setting value for position-setpoint smoothing is to be
read in.
index1: 0
Unit: -
Indices: 2
,BDS
Type: L2 ,K
,K
Menus:
- Parameter menu
+ Control/gating unit
+ Position control
- Upread/free access
Changeable in:
- Ready to switch on
- Operation enabled
P193*
S.Set PosSet
193
BICO parameter for selecting the binector from which the
command for setting position-setpoint smoothing is to be
read in.
index1: 0
Unit: -
Indices: 2
,BDS
Type: L2 ,B
Menus:
- Parameter menu
+ Control/gating unit
+ Position control
- Upread/free access
Changeable in:
- Ready to switch on
- Operation enabled
P194*
S.Pos ActV
194
BICO parameter for selecting the connector from which
the actual value for the position controller is to be read in.
index1: 120
Unit: -
Indices: 2
,BDS
Type: L2 ,K
,K
Menus:
- Parameter menu
+ Control/gating unit
+ Position control
- Upread/free access
Changeable in:
- Ready to switch on
34
Siemens AG 6SE7087-6QX70 (Edition AL)
SIMOVERT MASTERDRIVES Compendium Motion Control