Parameter
Description
Data
Read/write
P261*
S.Torq(conseq)
261
BICO parameter for selecting the connector from which
the torque setpoint is to be read in during "Slave drive"
operating mode.
index1: 0
Unit: -
Indices: 2
,BDS
Type: L2 ,K
Menus:
- Parameter menu
+ Control/gating unit
+ Speed control
- Upread/free access
Changeable in:
- Ready to switch on
- Operation enabled
P262*
S.Torque(add)
262
BICO parameter for selecting the connector from which
the additional setpoint for the torque is to be read in. The
additional setpoint is added to the setpoint of the torque
both in "Master drive" and "Slave drive" operating mode.
index1: 0
Unit: -
Indices: 2
,BDS
Type: L2 ,K
Menus:
- Parameter menu
+ Control/gating unit
+ Speed control
- Upread/free access
Changeable in:
- Ready to switch on
- Operation enabled
P263*
FSetpTorq(Lim1)
263
Function parameter for entering the fixed setpoint for the
upper torque limit. The parameter value entered relates to
the reference torque entered in P354.
IMPORTANT. Only positive values are permissible!
In function diagram 370.1
index1: 100,0
Min: -200,0
Max: 200,0
Unit: %
Indices: 4
,FDS
Type: I2
Menus:
- Parameter menu
+ Control/gating unit
+ Speed control
- Upread/free access
Changeable in:
- Ready to switch on
- Operation enabled
P264*
FSetpTorq(Lim2)
264
Function parameter for entering the fixed setpoint for the
lower torque limit. The parameter value entered relates to
the reference torque entered in P354.
IMPORTANT: Only negative values are permissible!
In function diagram 370.1
index1: -
100,0
Min: -200,0
Max: 200,0
Unit: %
Indices: 4
,FDS
Type: I2
Menus:
- Parameter menu
+ Control/gating unit
+ Speed control
- Upread/free access
Changeable in:
- Ready to switch on
- Operation enabled
P265*
S.Torq(Limit1)
265
BICO parameter for selecting the connector from which
the upper limit for the torque is to be read in.
index1: 170
Unit: -
Indices: 2
,BDS
Type: L2 ,K
Menus:
- Parameter menu
+ Control/gating unit
+ Speed control
- Upread/free access
Changeable in:
- Ready to switch on
- Operation enabled
P266*
S.Torq(Limit2)
266
BICO parameter for selecting the connector from which
the lower limit for the torque is to be read in.
index1: 171
Unit: -
Indices: 2
,BDS
Type: L2 ,K
Menus:
- Parameter menu
+ Control/gating unit
+ Speed control
- Upread/free access
Changeable in:
- Ready to switch on
- Operation enabled
P267*
S.Torque(add3)
267
BICO parameter for selecting the connector from which
the supplementary setpoint for the torque is to be read in.
The supplementary setpoint is added to the limited
setpoint of the torque, i.e the addition takes place behind
the limitation of the torque.
index1: 0
Unit: -
Indices: 2
,BDS
Type: L2 ,K
Menus:
- Parameter menu
- Upread/free access
Changeable in:
- Ready to switch on
- Operation enabled
r269
Torq (set, Lim)
269
Visualization parameter for displaying the torque setpoint
after limitation.
Dec.Plc.: 1
Unit: Nm
Indices: -
Type: I4
Menus:
- Parameter menu
+ Control/gating unit
+ Speed control
- Upread/free access
44
Siemens AG 6SE7087-6QX70 (Edition AL)
SIMOVERT MASTERDRIVES Compendium Motion Control