Parameter
Description
Data
Read/write
U080*
S.Bin/ConnC3
2080
BICO parameter for selecting the binectors for
binector/connector converter 3.
index1: 0
Unit: -
Indices: 16
Type: L2 ,B
Menus:
- Parameter menu
+ Free blocks
- Upread/free access
Changeable in:
- Ready to switch on
- Operation enabled
n081
# Bin/ConnC3
2081
Visualization parameter of binector/connector converter 3. Dec.Plc.: 0
Unit: -
Indices: -
Type: V2
Menus:
- Parameter menu
+ Free blocks
- Upread/free access
U082*
S.Conn Add 1
2082
BICO parameter for selecting the connectors for adder 1
(1 word).
index1: 0
Unit: -
Indices: 2
Type: L2 ,K
Menus:
- Parameter menu
+ Free blocks
- Upread/free access
Changeable in:
- Ready to switch on
- Operation enabled
U083*
S.Conn Add 2
2083
BICO parameter for selecting the connectors for adder 2
(1 word).
index1: 0
Unit: -
Indices: 2
Type: L2 ,K
Menus:
- Parameter menu
+ Free blocks
- Upread/free access
Changeable in:
- Ready to switch on
- Operation enabled
U084*
S.Conn Add 3
2084
BICO parameter for selecting the connectors for adder 3
(1 word).
index1: 0
Unit: -
Indices: 2
Type: L2 ,K
Menus:
- Parameter menu
+ Free blocks
- Upread/free access
Changeable in:
- Ready to switch on
- Operation enabled
U085*
S.Conn Add 4
2085
BICO parameter for selecting the connectors for adder 4
(1 word).
index1: 0
Unit: -
Indices: 2
Type: L2 ,K
Menus:
- Parameter menu
+ Free blocks
- Upread/free access
Changeable in:
- Ready to switch on
- Operation enabled
U086*
S.Conn Add 5
2086
BICO parameter for selecting the connectors for adder 5
with four inputs (1 word).
index1: 0
Unit: -
Indices: 4
Type: L2 ,K
Menus:
- Parameter menu
+ Free blocks
- Upread/free access
Changeable in:
- Ready to switch on
- Operation enabled
U087*
S.ConnSub1
2087
BICO parameter for selecting the connectors for
subtracter 1 (1 word).
index1: 0
Unit: -
Indices: 2
Type: L2 ,K
Menus:
- Parameter menu
+ Free blocks
- Upread/free access
Changeable in:
- Ready to switch on
- Operation enabled
U088*
S.ConnSub2
2088
BICO parameter for selecting the connectors for
subtracter 2 (1 word).
index1: 0
Unit: -
Indices: 2
Type: L2 ,K
Menus:
- Parameter menu
+ Free blocks
- Upread/free access
Changeable in:
- Ready to switch on
- Operation enabled
131
Siemens AG 6SE7087-6QX70 (Edition AL)
SIMOVERT MASTERDRIVES Compendium Motion Control