Parameter
Description
Data
Read/write
U151*
S.DConnLmtMon2
2151
BICO parameter for selecting the connector for the 2nd
limit-value monitor without smoothing (2 word).
index1: 0
Unit: -
Indices: 2
Type: L2 ,K
,K
Menus:
- Parameter menu
+ Free blocks
- Upread/free access
Changeable in:
- Ready to switch on
- Operation enabled
U152
HysDConnLmtMon2
2152
Function parameter for entering the hysteresis of the 2nd
limit-value monitor without smoothing (2 word).
Init: 0,00
Min: 0,00
Max: 199,99
Unit: %
Indices: -
Type: O4
Menus:
- Parameter menu
+ Free blocks
- Upread/free access
Changeable in:
- Ready to switch on
- Operation enabled
U153*
ModeDConnLmtMon
2
2153
Function parameters for entering the mode of the 2nd limit-
value monitor without smoothing (2 word).
Init: 0
Min: 0
Max: 2
Unit: -
Indices: -
Type: O2
Menus:
- Parameter menu
+ Free blocks
- Upread/free access
Changeable in:
- Ready to switch on
U154*
S.Cam 1/2
2154
BICO parameter for selecting the connector for the cam
controller with cam 1 and cam 2.
Init: 0
Unit: -
Indices: -
Type: L2 ,K
,K
Menus:
- Parameter menu
+ Free blocks
- Upread/free access
Changeable in:
- Ready to switch on
- Operation enabled
U155
Hys Cam 1/2
2155
Function parameter for entering the hysteresis of the cam
controller with cam 1 and cam 2.
index1: 0
Min: 0
Max:
2147483647
Unit: -
Indices: 2
Type: O4
Menus:
- Parameter menu
+ Free blocks
- Upread/free access
Changeable in:
- Ready to switch on
- Operation enabled
U156
ON-Pos Cam1
2156
Function parameter for entering the ON-position of cam 1.
The value of the ON position must be smaller than that of
the OFF position.
index1: 0
Min: -
2147483647
Max:
2147483647
Unit: -
Indices: 4
,FDS
Type: I4
Menus:
- Parameter menu
+ Free blocks
- Upread/free access
Changeable in:
- Ready to switch on
- Operation enabled
U157
OFF-Pos Cam1
2157
Function parameter for entering the OFF-position of cam
1.
index1: 0
Min: -
2147483647
Max:
2147483647
Unit: -
Indices: 4
,FDS
Type: I4
Menus:
- Parameter menu
+ Free blocks
- Upread/free access
Changeable in:
- Ready to switch on
- Operation enabled
U158
ON-Pos Cam2
2158
Function parameter for entering the ON-Position of cam 2. index1: 0
Min: -
2147483647
Max:
2147483647
Unit: -
Indices: 4
,FDS
Type: I4
Menus:
- Parameter menu
+ Free blocks
- Upread/free access
Changeable in:
- Ready to switch on
- Operation enabled
139
Siemens AG 6SE7087-6QX70 (Edition AL)
SIMOVERT MASTERDRIVES Compendium Motion Control