Parameter
Description
Data
Read/write
U369
TeCntrFStpOutLim
2369
Parameter for entering a fixed setpoint value for the
output limitation ramp-function generator of the
technology controller.
Init: 100,0
Min: 0,0
Max: 200,0
Unit: %
Indices: -
Type: I2
Menus:
- Parameter menu
+ Free blocks
- Upread/free access
Changeable in:
- Ready to switch on
U370*
S.TeCntrOutLim
2370
BICO parameter for selecting the connectors for the
output limitation of the technology controller.
Index 1: Connector for upper output limitation (B+)
Index 2: Connector for lower output limitation (B-)
index1: 586
Unit: -
Indices: 2
Type: L2 ,K
Menus:
- Parameter menu
+ Free blocks
- Upread/free access
Changeable in:
- Ready to switch on
- Operation enabled
U371
TeCntrOutLimTime
2371
Parameter for entering the acceleration/deceleration time
for the output limitation of the technology controller.
Init: 0,00
Min: 0,00
Max: 100,00
Unit: s
Indices: -
Type: O2
Menus:
- Parameter menu
+ Free blocks
- Upread/free access
Changeable in:
- Ready to switch on
- Operation enabled
n372
TeCntr Output
2372
Visualization parameter, output of the technology
controller after output limitation.
Dec.Plc.: 1
Unit: %
Indices: -
Type: I2
Menus:
- Parameter menu
+ Free blocks
- Upread/free access
U373*
S.J_Ext
2373
BICO parameter for selecting the connector from which
the moment of inertia for torque pre-control is read in.
index1: 0
Unit: -
Indices: 2
,BDS
Type: L2 ,K
Menus:
- Parameter menu
+ Control/gating unit
+ Speed control
- Upread/free access
Changeable in:
- Ready to switch on
- Operation enabled
U374*
S.AccPre
2374
BICO parameter for selecting a connector from which the
acceleration for torque pre-control is read in.
index1: 0
Unit: -
Indices: 2
,BDS
Type: L2 ,K
,K
Menus:
- Parameter menu
+ Control/gating unit
+ Speed control
- Upread/free access
Changeable in:
- Ready to switch on
- Operation enabled
U375*
S.T FixVal
2375
BICO parameter for selecting a connector from which a
fixed torque pre-control value is read in.
index1: 0
Unit: -
Indices: 2
,BDS
Type: L2 ,K
Menus:
- Parameter menu
+ Control/gating unit
+ Speed control
- Upread/free access
Changeable in:
- Ready to switch on
- Operation enabled
U376*
S.Select J
2376
BICO parameter for selecting a binector from which the
command to select a fixed (U378) or a variable moment of
inertia (U373) for torque pre-control is read in
index1: 0
Unit: -
Indices: 2
,BDS
Type: L2 ,B
Menus:
- Parameter menu
+ Control/gating unit
+ Speed control
- Upread/free access
Changeable in:
- Ready to switch on
- Operation enabled
163
Siemens AG 6SE7087-6QX70 (Edition AL)
SIMOVERT MASTERDRIVES Compendium Motion Control