Connector number
Connector name
Description
Double word
DSP
KK0857
MasVal pos diff
Master-value correction function in
function diagram 845:
Position difference beween master
value 1 and master value 2
yes
no
KK0858
LWcor DeltaV LW
Master-value correction function in
function diagram 845:
Speed difference beween master
value 1 and master value 2
yes
no
K0859
Override.fixed
Fixed connector for the speed override
of positioning
In function diagram: 809.1
no
no
KK0860
Pos CntrSignal
Connector contains the control signals
for positioning compiled from the
individual binectors
In function diagram: 809.6
yes
no
KK0861
32BGear 1 POS
Position setpoint output of the 32Bit
gear unit
yes
no
KK0862
32BGear 1 VSetp
Speed setpoint output of the 32Bit
gear unit
[FD786c]
yes
no
KK0863
32BGear 2 POS
Position setpoint output of the 32Bit
gear unit
yes
no
KK0864
32BGear 2 VSetp
Speed setpoint output of the 32Bit
gear unit
[FD786c]
yes
no
KK0866
LWcor DiffVRest
Master setpoint correction function in
function diagram 845b:
Speed difference still to be reduced
between master setpoint 1 and master
setpoint 2
yes
no
KK0867
FB_DisplActVal2
Output of offset adder 2 with limitation
to ACL
[LU] 32 Bit
[FD794a]
yes
no
KK0868
FB_DisplActVal3
Output of offset adder 3 with limitation
to ACL
[LU] 32 Bit
[FD794a]
yes
no
KK0870
BPos RFG V out
32 bit % speed output of basic
positioner ramp generator, see
function diagram 789b.8
yes
no
KK0871
BPos RFG S out
32 bit position setpoint output [LU] of
basic positioner ramp generator, see
function diagram 789b.8
yes
no
K0872 ... K0873
BP Set A Setp
16 bit set setpoint connector (%) of
basic positioner acceleration
setpoints.
See function diagram 789a.7
no
no
KK0874
BP Set V Setp
32 bit set setpoint connector (%) of
basic positioner. For valid speed
setpoint see function diagram 789a.7
yes
no
KK0875
BP Set S Setp
32 bit set setpoint connector (LU) of
basic positioner. For valid position
setpoint see function diagram 789a.7
yes
no
KK0876
BP FK V Setp
32 bit fixed setpoint connector (LU) of
basic positioner. Speed setpoint from
U873.1, see function diagram 789a.7
yes
no
K0877 ... K0878
BP FK A Setp
16 bit fixed setpoint connector (%) of
basic positioner. Acceleration
setpoints from U873.2,3.
see function diagram 789a.7
no
no
25
Siemens AG 6SE7087-6QX70 (Edition AL)
SIMOVERT MASTERDRIVES Compendium Motion Control