Parameterization
03.2010
6SE7087-6QX70 (Version AL) Siemens AG
5-28
Compendium Motion Control
SIMOVERT MASTERDRIVES
A fault or alarm message is indicated by the red LED. In the event of a
fault, the red LED lights up and stays on. A fault message appears in
the 3rd and 4th line of the operating display.
0.0 A 0 V 00
#
0.00 min-1
F065: SCom Tlg
Fault
1/1
∇
0.0 A 0 V 00
#
0.00 min-1
1T 3h 2"
Fault
1/1
Example of a fault display
The fault number and the respective text are shown in the 3rd line. Up
to 8 fault messages can be stored but only the first fault to occur is
shown on the display. Several subsequent faults are shown in the 4th
line, e.g. with 1/3 (first of three). Information on all faults can be
obtained from the fault memory. With "Raise"/"Lower", the associated
operating hours are shown when a fault is waiting to be remedied.
After the cause of a fault has been removed, the fault is acknowledged
with "Reset" inside the operating display (the "Reset" key must be
appropriately parameterized. See section "Issuing commands via the
OP1S"). By pressing "P" and "Lower" at the same time, it is possible to
skip back directly to the operating display from the parameter level.
When there is an alarm, the red LED flashes. A warning appears in the
4th line of the operating display.
8.2 A 520 V 00
#
100.00 min-1
*
100.00 min-1
-33:Overspeed
Example of an alarm display
The alarm number and the respective text is shown in the 4th line.
There can be several alarms at the same time but only the first alarm to
occur is shown on the display. Several alarms are shown in the 4th line
before the alarm number with an "+” instead of "
−
”. Information on all
alarms can be obtained with the alarm parameters r953 to r969.
An alarm cannot be acknowledged. As soon as the cause no longer
exists, the alarm/display disappears automatically.
Fault and alarm
messages