SIMPRO-100
SIMPRO-PC Compatibility Features
D
PRIM-2400C
189
D SIMPRO-PC Compatibility Features
D.1
Introduction
This appendix describes communication features
that the SIMPRO-100 Relay serial ports support
when they are configured for ASCII
communications. These functions are not
provided on the relay EIA-485 port when it is
configured for Modbus
™
protocol support.
Siemens relays have two separate data streams
that share the same EIA-232 serial port. The
relay supports communication with people using
ASCII character commands and formatted
responses that are intelligible using a terminal or
terminal emulation package. In addition, the relay
includes a class of compressed-ASCII commands
intended for use by the SIMPRO-PC software.
These command responses include ASCII
characters but are formatted in a way that makes
them more compact. They are typically better
suited to software analysis than analysis using a
terminal emulation package.
Interleaved with the ASCII data stream, the relay
can receive and respond to a set of binary
commands. This mechanism allows a single
communications channel to be used for ASCII
communications (e.g., transmission of a long
event report) interleaved with short bursts of
binary data to support fast acquisition of metering
data. The requesting device must be equipped to
execute the binary commands, then separate and
interpret the binary response. The binary
commands and ASCII commands can also be
accessed by a device that does not interleave the
data streams.
D.2
Fast Binary Message
Lists
Table D.1
Binary Message List
Table D.2
ASCII Configuration Message List
Request
to Relay
Response From Relay
Hex
A5C0
Relay Definition Block
A5C1
Fast Meter Configuration Block
A5D1
Fast Meter Data Block
A5C2
Demand Fast Meter Configuration Block
A5D2
Demand Fast Meter Data Message
A5C3
Peak Demand Fast Meter Configuration Block
A5D3
Peak Demand Fast Meter Data Message
A5B9
Fast Meter Status Acknowledge
A5CE
Fast Operate Configuration Block
A5E0
Fast Operate Remote Bit Control
A5E3
Fast Operate Breaker/Contactor Control
Request
to Relay
Response From Relay
ASCII
ID
ASCII Relay Identification and Configuration
Strings
DNA
ASCII Names of Relay Word Bits
BNA
ASCII Names of Bits in the A5B9 Status Byte
Summary of Contents for SIMPRO-100
Page 1: ...SIMPRO 100 Motor Protection Relay Instruction Manual Document No PRIM 2400C ...
Page 12: ...Contents SIMPRO 100 x PRIM 2400C ...
Page 16: ...Contents SIMPRO 100 xiv PRIM 2400C ...
Page 42: ...3 SIMPRO PC Software SIMPRO 100 40 PRIM 2400C ...
Page 100: ...6 ASCII Serial Port Operation SIMPRO 100 98 PRIM 2400C ...
Page 127: ...SIMPRO 100 Event Analysis 9 PRIM 2400C 125 Figure 9 2 Example SER Report ...
Page 136: ...10 Maintenance Troubleshooting SIMPRO 100 134 PRIM 2400C ...
Page 138: ...A Firmware Versions SIMPRO 100 136 PRIM 2400C ...
Page 206: ...D SIMPRO PC Compatibility Features SIMPRO 100 204 PRIM 2400C ...
Page 214: ...E Motor Thermal Element SIMPRO 100 212 PRIM 2400C ...
Page 230: ...F SIMPRO 100 Relay Settings Sheets SIMPRO 100 228 PRIM 2400C ...
Page 239: ......