2 Parameters
2.2 List of parameters
Re index 2 ...3:
The triggering PIN for trace 0 is entered here.
Index 2 bit 31 ... 16: Number of the Drive Object (DO), bit 15 ... 0: Number of the chart
Index 3 bit 31 ... 16: Number of the block, bit 15 ... 0: Number of the PIN
Re index 4 ... 5:
The triggering PIN for trace 1 is entered here.
Index 4 bit 31 ... 16: Number of the Drive Object (DO), bit 15 ... 0: Number of the chart
Index 5 bit 31 ... 16: Number of the block, bit 15 ... 0: Number of the PIN
Description:
Sets the trigger threshold for the trace.
Index:
[0] = Trace 0
[1] = Trace 1
Dependency:
Only effective when p4710 = 2, 3.
Description:
Sets the first trigger threshold for trigger via tolerance band.
Index:
[0] = Trace 0
[1] = Trace 1
Dependency:
Only effective when p4710 = 4, 5.
Description:
Sets the second trigger threshold for trigger via tolerance band
Index:
[0] = Trace 0
[1] = Trace 1
Dependency:
Only effective when p4710 = 4, 5.
Description:
Sets the bit mask for the bit mask trigger.
p4712[0...1]
Trace trigger threshold / Trace trig_thresh
CU_DC, CU_DC_R,
CU_DC_R_S,
CU_DC_S
Can be changed:
U, T
Calculated:
-
Access level:
3
Data type:
FloatingPoint32
Dyn. index:
-
Func. diagram:
-
P-Group:
Trace and function generator
Unit group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
0
Min Max
Factory
setting
-340.28235E36 340.28235E36
0.00
p4713[0...1]
Trace tolerance band trigger threshold 1 / Trace trig thr 1
CU_DC, CU_DC_R,
CU_DC_R_S,
CU_DC_S
Can be changed:
U, T
Calculated:
-
Access level:
3
Data type:
FloatingPoint32
Dyn. index:
-
Func. diagram:
-
P-Group:
Trace and function generator
Unit group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
0
Min Max
Factory
setting
-340.28235E36 340.28235E36
0.00
p4714[0...1]
Trace tolerance band trigger threshold 2 / Trace trig thr 2
CU_DC, CU_DC_R,
CU_DC_R_S,
CU_DC_S
Can be changed:
U, T
Calculated:
-
Access level:
3
Data type:
FloatingPoint32
Dyn. index:
-
Func. diagram:
-
P-Group:
Trace and function generator
Unit group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
0
Min Max
Factory
setting
-340.28235E36 340.28235E36
0.00
p4715[0...1]
Trace bit mask trigger, bit mask / Trace trig mask
CU_DC, CU_DC_R,
CU_DC_R_S,
CU_DC_S
Can be changed:
U, T
Calculated:
-
Access level:
3
Data type:
Unsigned32
Dyn. index:
-
Func. diagram:
-
P-Group:
Trace and function generator
Unit group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
0
Min Max
Factory
setting
0 4294967295
0