Description:
Sets the scaling for the amplitude of the signal waveforms for all output channels.
The value can be changed while the function generator is running.
Description:
Sets the scaling for the amplitude of the signal waveforms separately for each output channel.
The value cannot be changed while the function generator is running.
Index:
[0] = First drive for connection
[1] = Second drive for connection
[2] = Third drive for connection
Description:
Sets the scaling for the offset of the signal waveforms separately for each output channel.
The value cannot be changed while the function generator is running.
Index:
[0] = First drive for connection
[1] = Second drive for connection
[2] = Third drive for connection
Description:
Displays the output signal for the free measurement function.
Index:
[0] = Signal 1
[1] = Signal 2
[2] = Signal 3
[3] = Signal 4
[4] = Signal 5
Dependency:
Refer to: p4810
Note:
The signals are only output in the "free measurement function" operating mode (p4810 = 6)
p4831
Function generator amplitude scaling / FG amplitude scal
CU_DC, CU_DC_R,
CU_DC_R_S,
CU_DC_S
Can be changed:
U, T
Calculated:
-
Access level:
3
Data type:
FloatingPoint32
Dyn. index:
-
Func. diagram:
-
P-Group:
Trace and function generator
Unit group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
0
Min Max
Factory
setting
0.00000 [%]
200.00000 [%]
100.00000 [%]
p4832[0...2]
Function generator amplitude scaling / FG amplitude scal
CU_DC, CU_DC_R,
CU_DC_R_S,
CU_DC_S
Can be changed:
U, T
Calculated:
-
Access level:
3
Data type:
FloatingPoint32
Dyn. index:
-
Func. diagram:
-
P-Group:
Trace and function generator
Unit group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
0
Min Max
Factory
setting
-340.28235E36 [%]
340.28235E36 [%]
100.00000 [%]
p4833[0...2]
Function generator offset scaling / FG offset scal
CU_DC, CU_DC_R,
CU_DC_R_S,
CU_DC_S
Can be changed:
U, T
Calculated:
-
Access level:
3
Data type:
FloatingPoint32
Dyn. index:
-
Func. diagram:
-
P-Group:
Trace and function generator
Unit group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
0
Min Max
Factory
setting
-340.28235E36 [%]
340.28235E36 [%]
100.00000 [%]
r4834[0...4]
CO: Function generator free measurement output signal / FG fr MeasFct outp
CU_DC, CU_DC_R,
CU_DC_R_S,
CU_DC_S
Can be changed:
-
Calculated:
-
Access level:
3
Data type:
FloatingPoint32
Dyn. index:
-
Func. diagram:
-
P-Group:
Trace and function generator
Unit group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
PERCENT
Expert list:
0
Min Max
Factory
setting
- [%]
- [%]
- [%]