SINAMICS DCM
List Manual (LH8), 02/2015, 6RX1800-0ED76
297
2 Parameters
2.2 List of parameters
Value:
0:
Deactivated
1:
Upgrade and downgrade
2:
Upgrade
Notice:
If this parameter is changed, it only becomes effective the next time that the drive system boots.
Note:
The firmware is automatically updated when the system boots. The boot can take several minutes.
After the update has been completed, it is necessary to carry out a new POWER ON (power-down/power-up) for the
components involved.
The firmware update procedure is displayed as follows:
Control Unit (LED RDY):
Flashes yellow with 0.5 Hz --> firmware is being updated.
Flashing yellow with 2 Hz --> POWER ON is required for the components involved.
Components involved:
Flashing red/green with 0.5 Hz --> firmware is being updated.
Flashing red/green with 2 Hz --> POWER ON of the components is required.
Only components from firmware version 2.5 support the red/green flashing at 2 Hz.
Description:
Displays the progress when updating the firmware of the DRIVE-CLiQ components.
Description:
Sets the component number for the required DRIVE-CLiQ component.
Index 0:
Component number of the DRIVE-CLiQ component for which a firmware download is to be made.
Index 1:
Component number of the DRIVE-CLiQ component for which the reference firmware version, saved in r7825 on the
memory card/device memory, is to be displayed.
Index:
[0] = Firmware download
[1] = Reference firmware version
Dependency:
Refer to: p0121, p0141, p0151, p7829
Note:
For p7828[0] = 399, the firmware for all of the existing components is downloaded.
The firmware download is started with p7829 = 1.
Description:
Activating the firmware download for the DRIVE-CLiQ components specified in p7828.
r7827
Firmware update progress display / FW update progress
CU_DC, CU_DC_R,
CU_DC_R_S,
CU_DC_S
Can be changed:
-
Calculated:
-
Access level:
3
Data type:
FloatingPoint32
Dyn. index:
-
Func. diagram:
-
P-Group:
-
Unit group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
- [%]
- [%]
- [%]
p7828[0...1]
Firmware download component number / FW downl comp_no
CU_DC, CU_DC_R,
CU_DC_R_S,
CU_DC_S
Can be changed:
U, T
Calculated:
-
Access level:
3
Data type:
Unsigned16
Dyn. index:
-
Func. diagram:
-
P-Group:
-
Unit group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
0 399
0
p7829
Activate firmware download / FW download act
CU_DC, CU_DC_R,
CU_DC_R_S,
CU_DC_S
Can be changed:
U, T
Calculated:
-
Access level:
3
Data type:
Integer16
Dyn. index:
-
Func. diagram:
-
P-Group:
-
Unit group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
-1 999
0
Summary of Contents for SINAMICS DCM
Page 1: ...s SINAMICS SINAMICS DCM List Manual 02 2015 Edition Answers for industry ...
Page 2: ......
Page 1192: ...A Appendix A 2 List of abbreviations SINAMICS DCM 1192 List Manual LH8 02 2015 6RX1800 0ED76 ...
Page 1202: ...Index SINAMICS DCM 1202 List Manual LH8 02 2015 6RX1800 0ED76 ...
Page 1203: ......