SINAMICS DCM
List Manual (LH8), 02/2015, 6RX1800-0ED76
313
2 Parameters
2.2 List of parameters
Description:
Displays the ACX file saved in the appropriate directory in the non-volatile memory.
Dependency:
Refer to: p1500
Note:
For a value = 9999999, the following applies: The read operation is still running.
Description:
Displays the macro currently being executed on the drive object.
Dependency:
Refer to: p0015, p0700, p1000, p1500, r8570, r8571, r8572, r8573
Description:
Sets the configuration for the content of identification and maintenance 4 (I&M 4, p8809).
Value:
0:
Standard value for I&M 4 (p8809)
1:
User value for I&M 4 (p8809)
Dependency:
For p8805 = 0, if the user writes at least one value in p8809[0...53], then p8805 is automatically set to = 1.
When p8805 is reset = 0, then the content of the factory setting is set in p8809.
Note:
Re p8805 = 0:
PROFINET I&M 4 (p8809) contains the information for the SI change tracking.
Re p8805 = 1:
PROFINET I&M 4 (p8809) contains the values written by the user.
Description:
Parameters for the PROFINET data set "Identification and Maintenance 1" (I&M 1).
This information is known as "System identifier" and "Location identifier".
Dependency:
Refer to: p8807, p8808
Notice:
Only characters belonging to the standard ASCII character set may be used (32 dec to 126 dec).
r8573[0...39]
Macro Connector Inputs (CI) for torque setpoints / Macro CI M_set
DC_CTRL,
DC_CTRL_R,
DC_CTRL_R_S,
DC_CTRL_S
Can be changed:
-
Calculated:
-
Access level:
1
Data type:
Unsigned32
Dyn. index:
-
Func. diagram:
-
P-Group:
-
Unit group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
0
Min Max
Factory
setting
- -
-
r8585
Macro execution actual / Macro executed
All objects
Can be changed:
-
Calculated:
-
Access level:
1
Data type:
Unsigned16
Dyn. index:
-
Func. diagram:
-
P-Group:
-
Unit group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
0
Min Max
Factory
setting
- -
-
p8805
Identification and maintenance 4 configuration / I&M 4 config
CU_DC, CU_DC_R,
CU_DC_R_S,
CU_DC_S
Can be changed:
U, T
Calculated:
-
Access level:
3
Data type:
Integer16
Dyn. index:
-
Func. diagram:
-
P-Group:
-
Unit group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
0 1
0
p8806[0...53]
Identification and Maintenance 1 / I&M 1
CU_DC, CU_DC_R,
CU_DC_R_S,
CU_DC_S
Can be changed:
U, T
Calculated:
-
Access level:
3
Data type:
Unsigned8
Dyn. index:
-
Func. diagram:
-
P-Group:
-
Unit group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
- -
Summary of Contents for SINAMICS DCM
Page 1: ...s SINAMICS SINAMICS DCM List Manual 02 2015 Edition Answers for industry ...
Page 2: ......
Page 1192: ...A Appendix A 2 List of abbreviations SINAMICS DCM 1192 List Manual LH8 02 2015 6RX1800 0ED76 ...
Page 1202: ...Index SINAMICS DCM 1202 List Manual LH8 02 2015 6RX1800 0ED76 ...
Page 1203: ......