2 Parameters
2.2 List of parameters
SINAMICS DCM
492
List Manual (LH8), 02/2015, 6RX1800-0ED76
Note:
The valuation factors affect the set values of the following parameters:
- p50303: Ramp-up time 1
- p50304: Ramp-down time 1
- p50305: Initial rounding 1
- p50306: Final rounding 1
Description:
Sets the signal source for the selection of "ramp-function generator parameter set 2".
1 signal:
RFG parameter set 2 is effective (p50307, p50308, p50309, p50310).
Dependency:
Refer to: p50307, p50308, p50309, p50310, p50638
Refer to: F60041
Note:
The following applies as regards selection of ramp-function generator parameter set 2:
- This selection has a higher priority than selection by means of the ramp-up integrator.
- This selection has a lower priority than quick stop (OFF3); in other words, in the event of a quick stop (OFF3) the
values set in p50296, p50297, and p50298 become effective.
- A corresponding message is output if ramp-function generator parameter sets 2 and 3 are selected at the same
time.
Description:
Sets the signal source for the selection of "ramp-function generator parameter set 3".
1 signal:
RFG parameter set 3 is effective (p50311, p50312, p50313, p50314).
Dependency:
Refer to: p50311, p50312, p50313, p50314, p50637
Refer to: F60041
Note:
The following applies as regards selection of ramp-function generator parameter set 3:
- This selection has a higher priority than selection by means of the ramp-up integrator.
- This selection has a lower priority than quick stop (OFF3); in other words, in the event of a quick stop (OFF3) the
values set in p50296, p50297, and p50298 become effective.
- A corresponding message is output if ramp-function generator parameter sets 2 and 3 are selected at the same
time.
Description:
Sets the signal source for the ramp-function generator's setting values.
Index:
[0] = Setting value
[1] = Setting value if machine is not running
p50637[0...n]
BI: RFG parameter set 2 selection signal source / RFG par s 2 sig s
DC_CTRL
Can be changed:
T
Calculated:
-
Access level:
3
Data type:
Unsigned32 / Binary
Dyn. index:
CDS, p0170
Func. diagram:
3150
P-Group:
-
Unit group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
- -
0
p50638[0...n]
BI: RFG parameter set 3 selection signal source / RFG par s 3 sig s
DC_CTRL
Can be changed:
T
Calculated:
-
Access level:
3
Data type:
Unsigned32 / Binary
Dyn. index:
CDS, p0170
Func. diagram:
3150
P-Group:
-
Unit group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
- -
0
p50639[0...1]
CI: RFG signal source for setting value / RFG set val sig s
DC_CTRL
Can be changed:
T
Calculated:
-
Access level:
3
Data type:
Unsigned32 / FloatingPoint32
Dyn. index:
-
Func. diagram:
3152
P-Group:
-
Unit group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
PERCENT
Expert list:
1
Min Max
Factory
setting
- -
52167[0]