2 Parameters
2.2 List of parameters
SINAMICS DCM
544
List Manual (LH8), 02/2015, 6RX1800-0ED76
Description:
Sets the line voltage at the diode bridge for a 6-pulse/12-pulse series circuit of a SINAMICS DCM with an
uncontrolled rectifier (diode bridge).
Note:
The value set here is a percentage of the line voltage at the SINAMICS DCM.
Description:
Sets the mode of operation of the armature converter
Value:
0:
Standard mode of operation
1:
Sole power unit 1-phase
3:
Sole power unit 3-phase
21:
12-pulse parallel, firing angle from the master
22:
12-pulse parallel, firing angle master/slave
31:
6-pulse serial, firing angle from the master
32:
6-pulse serial with sequential phase control
41:
12-pulse serial, firing angle from the master
42:
12-pulse serial with sequential phase control
Dependency:
Refer to: p51797, p51800
Note:
If value = 0:
Standard for the corresponding topology (acc. to p51800).
If value = 1:
Sole power unit in 1-phase operation (line connection at inputs 1U and 1V).
If value = 3:
Sole power unit in 3-phase operation (= standard).
If value = 21:
12-pulse parallel connection with central firing angle generation in the master (= standard).
If value = 22:
12-pulse parallel connection with current setpoint interface, own closed-loop current control and firing angle
generation in the master and in the slave.
If value = 31:
6-pulse series circuit with central firing pulse generation in the master (= standard).
If value = 32:
6-pulse series connection with sequential phase control.
If value = 41:
12-pulse series circuit with central firing pulse generation in the master (= standard).
If value = 42:
12-pulse series connection with sequential phase control.
p51798
Armature converter voltage diode bridge / Ia_convert U diode
DC_CTRL
Can be changed:
T
Calculated:
-
Access level:
3
Data type:
FloatingPoint32
Dyn. index:
-
Func. diagram:
6902
P-Group:
-
Unit group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
PERCENT
Expert list:
1
Min Max
Factory
setting
50.00 [%]
100.00 [%]
85.00 [%]
p51799
Armature converter mode of operation / Ia_conv mode_op
DC_CTRL
Can be changed:
T
Calculated:
-
Access level:
3
Data type:
Integer16
Dyn. index:
-
Func. diagram:
6855
P-Group:
-
Unit group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
0 42
0