2 Parameters
2.2 List of parameters
SINAMICS DCM
570
List Manual (LH8), 02/2015, 6RX1800-0ED76
Description:
Display and connector output for the current controller setpoint prior to absolute value generation for closed-loop
armature current control.
Description:
Display and connector output for the current controller setpoint before reduced gearbox stressing.
Description:
Display and connector output for the armature current pre-control output.
Description:
Display and connector output for the EMF actual value for armature current pre-control.
Note:
100% corresponds to p50078[0] * (3 * sqrt(2)) / Pi.
Description:
Display and connector output for the signed unsmoothed EMF actual value.
Note:
100% corresponds to p50078[0] * (3 * sqrt(2)) / Pi.
r52119
CO: Cl-loop arm curr control curr controller setpoint / Ia ctr I_set
DC_CTRL
Can be changed:
-
Calculated:
-
Access level:
2
Data type:
FloatingPoint32
Dyn. index:
-
Func. diagram:
6855
P-Group:
-
Unit group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
PERCENT
Expert list:
1
Min Max
Factory
setting
- [%]
- [%]
- [%]
r52120
CO: Curr limitation arm curr setpoint before red gearbox stressing / Ia_set bef gear
DC_CTRL
Can be changed:
-
Calculated:
-
Access level:
1
Data type:
FloatingPoint32
Dyn. index:
-
Func. diagram:
6845
P-Group:
-
Unit group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
PERCENT
Expert list:
1
Min Max
Factory
setting
- [%]
- [%]
- [%]
r52121
CO: Closed-loop armature current control pre-control output / Ia ctr prec outp
DC_CTRL
Can be changed:
-
Calculated:
-
Access level:
1
Data type:
FloatingPoint32
Dyn. index:
-
Func. diagram:
6855
P-Group:
-
Unit group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
PERCENT
Expert list:
1
Min Max
Factory
setting
- [%]
- [%]
- [%]
r52122
CO: EMF actual value armature current pre-control / EMF act prec
DC_CTRL
Can be changed:
-
Calculated:
-
Access level:
2
Data type:
FloatingPoint32
Dyn. index:
-
Func. diagram:
6852, 6855
P-Group:
-
Unit group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
PERCENT
Expert list:
1
Min Max
Factory
setting
- [%]
- [%]
- [%]
r52123
CO: EMF actual value signed / EMF act sign
DC_CTRL
Can be changed:
-
Calculated:
-
Access level:
2
Data type:
FloatingPoint32
Dyn. index:
-
Func. diagram:
6852, 6902
P-Group:
-
Unit group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
PERCENT
Expert list:
1
Min Max
Factory
setting
- [%]
- [%]
- [%]
Summary of Contents for SINAMICS DCM
Page 1: ...s SINAMICS SINAMICS DCM List Manual 02 2015 Edition Answers for industry ...
Page 2: ......
Page 1192: ...A Appendix A 2 List of abbreviations SINAMICS DCM 1192 List Manual LH8 02 2015 6RX1800 0ED76 ...
Page 1202: ...Index SINAMICS DCM 1202 List Manual LH8 02 2015 6RX1800 0ED76 ...
Page 1203: ......