2 Parameters
2.2 List of parameters
SINAMICS DCM
576
List Manual (LH8), 02/2015, 6RX1800-0ED76
Description:
Display and connector output for acceleration dependent upon setpoint/actual value difference.
In the case of the "Acceleration dependent upon setpoint/actual value difference" function, only the proportion of the
speed controller's setpoint/actual value difference which has an absolute value in excess of the threshold (p50543) is
switched through.
Dependency:
Refer to: p50541, p50543
Description:
Display and connector output for the reference model for the speed controller.
Dependency:
Refer to: p50237, p50238, p50239
Description:
Display and connector output for the setpoint-actual value difference after the influence of the reference model for the
speed controller.
Dependency:
Refer to: p50621, p50622, p50623, p50624
Description:
Display and connector output for the output value of the lead/lag element.
Dependency:
Refer to: p50207, p50208, p50209
Description:
Display and connector output for the speed controller's output value.
r52152
CO: Speed controller setpoint/actual value difference output / Set/act dif outp
DC_CTRL
Can be changed:
-
Calculated:
-
Access level:
2
Data type:
FloatingPoint32
Dyn. index:
-
Func. diagram:
6820
P-Group:
-
Unit group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
PERCENT
Expert list:
1
Min Max
Factory
setting
- [%]
- [%]
- [%]
r52154
CO: Speed controller reference model output / n_ctrl ref outp
DC_CTRL
Can be changed:
-
Calculated:
-
Access level:
2
Data type:
FloatingPoint32
Dyn. index:
-
Func. diagram:
6812
P-Group:
-
Unit group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
PERCENT
Expert list:
1
Min Max
Factory
setting
- [%]
- [%]
- [%]
r52155
CO: Speed controller reference model setpoint-actual val difference / n_ctr ref set-act
DC_CTRL
Can be changed:
-
Calculated:
-
Access level:
2
Data type:
FloatingPoint32
Dyn. index:
-
Func. diagram:
6812
P-Group:
-
Unit group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
PERCENT
Expert list:
1
Min Max
Factory
setting
- [%]
- [%]
- [%]
r52156
CO: Lead/lag element output value / Lead/lag output
DC_CTRL
Can be changed:
-
Calculated:
-
Access level:
2
Data type:
FloatingPoint32
Dyn. index:
-
Func. diagram:
6810
P-Group:
-
Unit group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
PERCENT
Expert list:
1
Min Max
Factory
setting
- [%]
- [%]
- [%]
r52160
CO: Speed controller output value / n_ctr outp val
DC_CTRL
Can be changed:
-
Calculated:
-
Access level:
1
Data type:
FloatingPoint32
Dyn. index:
-
Func. diagram:
6815
P-Group:
-
Unit group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
PERCENT
Expert list:
1
Min Max
Factory
setting
- [%]
- [%]
- [%]
Summary of Contents for SINAMICS DCM
Page 1: ...s SINAMICS SINAMICS DCM List Manual 02 2015 Edition Answers for industry ...
Page 2: ......
Page 1192: ...A Appendix A 2 List of abbreviations SINAMICS DCM 1192 List Manual LH8 02 2015 6RX1800 0ED76 ...
Page 1202: ...Index SINAMICS DCM 1202 List Manual LH8 02 2015 6RX1800 0ED76 ...
Page 1203: ......