2 Parameters
2.2 List of parameters
SINAMICS DCM
578
List Manual (LH8), 02/2015, 6RX1800-0ED76
Description:
Display and connector output of the selected speed actual value on the speed controller.
Description:
Display and connector output for the negative output value of the derivative-action element.
Dependency:
Refer to: p50205, p50206, p50627, r52169
Description:
Display and connector output for the output value of the derivative-action element.
Dependency:
Refer to: p50205, p50206, p50627, r52168
Description:
Display and connector output for the speed setpoint after limiting.
Description:
Display and connector output of the compensation output value for friction and inertia.
Dependency:
Refer to: p50223
Note:
If p50223 = 1:
This value is added to the speed controller's output.
r52167
CO: Speed controller actual value selection / Act sel
DC_CTRL
Can be changed:
-
Calculated:
-
Access level:
1
Data type:
FloatingPoint32
Dyn. index:
-
Func. diagram:
6810
P-Group:
-
Unit group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
PERCENT
Expert list:
1
Min Max
Factory
setting
- [%]
- [%]
- [%]
r52168
CO: Derivative-action element negative output value / D elem neg outp
DC_CTRL
Can be changed:
-
Calculated:
-
Access level:
2
Data type:
FloatingPoint32
Dyn. index:
-
Func. diagram:
6810
P-Group:
-
Unit group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
PERCENT
Expert list:
1
Min Max
Factory
setting
- [%]
- [%]
- [%]
r52169
CO: Derivative-action element output value / D elem outp
DC_CTRL
Can be changed:
-
Calculated:
-
Access level:
2
Data type:
FloatingPoint32
Dyn. index:
-
Func. diagram:
6810
P-Group:
-
Unit group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
PERCENT
Expert list:
1
Min Max
Factory
setting
- [%]
- [%]
- [%]
r52170
CO: RFG speed setpoint after limiting / RFG n_set aft lim
DC_CTRL
Can be changed:
-
Calculated:
-
Access level:
1
Data type:
FloatingPoint32
Dyn. index:
-
Func. diagram:
1720, 3155
P-Group:
-
Unit group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
PERCENT
Expert list:
1
Min Max
Factory
setting
- [%]
- [%]
- [%]
r52171
CO: Friction/inertia compensation output value / Comp outp
DC_CTRL
Can be changed:
-
Calculated:
-
Access level:
2
Data type:
FloatingPoint32
Dyn. index:
-
Func. diagram:
6815, 6820
P-Group:
-
Unit group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
PERCENT
Expert list:
1
Min Max
Factory
setting
- [%]
- [%]
- [%]
Summary of Contents for SINAMICS DCM
Page 1: ...s SINAMICS SINAMICS DCM List Manual 02 2015 Edition Answers for industry ...
Page 2: ......
Page 1192: ...A Appendix A 2 List of abbreviations SINAMICS DCM 1192 List Manual LH8 02 2015 6RX1800 0ED76 ...
Page 1202: ...Index SINAMICS DCM 1202 List Manual LH8 02 2015 6RX1800 0ED76 ...
Page 1203: ......