2 Parameters
2.2 List of parameters
SINAMICS DCM
58
List Manual (LH8), 02/2015, 6RX1800-0ED76
Note:
Example:
The value 1010100 should be interpreted as V01.01.01.00.
Description:
Displays the firmware version of the Sensor Module.
Dependency:
Refer to: r0018, r0158, r0197, r0198
Note:
Example:
The value 1010100 should be interpreted as V01.01.01.00.
Description:
Sets the component number for the Terminal Module.
This unique component number is assigned when parameterizing the topology.
Only component numbers can be entered into this parameter that correspond to a Terminal Module.
Description:
Detects the Terminal Module assigned to this drive and data set.
Note:
While p0154 = 1, the READY LED flashes green/orange or red/orange with 2 Hz at the appropriate Terminal Module.
Description:
Displays the version of the EEPROM data of the Terminal Module.
Dependency:
Refer to: r0147
Note:
Example:
The value 1010100 should be interpreted as V01.01.01.00.
r0148[0...n]
Sensor Module firmware version / SM FW version
DC_CTRL,
DC_CTRL_R,
DC_CTRL_R_S,
DC_CTRL_S
Can be changed:
-
Calculated:
-
Access level:
3
Data type:
Unsigned32
Dyn. index:
EDS, p0140
Func. diagram:
-
P-Group:
Encoder
Unit group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
- -
-
p0151
Terminal Module component number / TM comp_no
TM150, TM15DI_DO,
TM31
Can be changed:
C1(4)
Calculated:
-
Access level:
3
Data type:
Unsigned8
Dyn. index:
-
Func. diagram:
-
P-Group:
Data sets
Unit group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
0 199
0
p0154
Terminal Module detection via LED / TM detection LED
TM150, TM15DI_DO,
TM31
Can be changed:
U, T
Calculated:
-
Access level:
2
Data type:
Unsigned8
Dyn. index:
-
Func. diagram:
-
P-Group:
Terminals
Unit group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
0 1
0
r0157
Terminal Module EEPROM data version / TM EEPROM version
TM150, TM15DI_DO,
TM31
Can be changed:
-
Calculated:
-
Access level:
3
Data type:
Unsigned32
Dyn. index:
-
Func. diagram:
-
P-Group:
Terminals
Unit group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
- -
-
Summary of Contents for SINAMICS DCM
Page 1: ...s SINAMICS SINAMICS DCM List Manual 02 2015 Edition Answers for industry ...
Page 2: ......
Page 1192: ...A Appendix A 2 List of abbreviations SINAMICS DCM 1192 List Manual LH8 02 2015 6RX1800 0ED76 ...
Page 1202: ...Index SINAMICS DCM 1202 List Manual LH8 02 2015 6RX1800 0ED76 ...
Page 1203: ......