2 Parameters
2.3 Parameters for data sets
SINAMICS DCM
646
List Manual (LH8), 02/2015, 6RX1800-0ED76
2.3
Parameters for data sets
2.3.1
Parameters for command data sets (CDS)
The following list contains the parameters that are dependent on the command data sets.
Product: SINAMICS DC MASTER, Version: 4702900, Language: eng, Type: CDS
Product: SINAMICS DC MASTER OA, Version: 1401800, Language: eng, Type: CDS
p0700[0...n]
Macro Binector Input (BI) / Macro BI
p0820[0...n]
BI: Drive Data Set selection DDS bit 0 / DDS select., bit 0
p0821[0...n]
BI: Drive Data Set selection DDS bit 1 / DDS select., bit 1
p0840[0...n]
BI: ON / OFF (OFF1) / ON / OFF (OFF1)
p0844[0...n]
BI: No coast-down / coast-down (OFF2) signal source 1 / OFF2 S_src 1
p0845[0...n]
BI: No coast-down / coast-down (OFF2) signal source 2 / OFF2 S_src 2
p0848[0...n]
BI: No Quick Stop / Quick Stop (OFF3) signal source 1 / OFF3 S_src 1
p0849[0...n]
BI: No Quick Stop / Quick Stop (OFF3) signal source 2 / OFF3 S_src 2
p0852[0...n]
BI: Enable operation/inhibit operation / Operation enable
p0854[0...n]
BI: Control by PLC/no control by PLC / Master ctrl by PLC
p0855[0...n]
BI: Unconditionally release holding brake / Uncond open brake
p0856[0...n]
BI: Speed controller enable / n_ctrl enable
p0858[0...n]
BI: Unconditionally close holding brake / Uncond close brake
p1000[0...n]
Macro Connector Inputs (CI) for speed setpoints / Macro CI n_set
p1035[0...n]
BI: Motorized potentiometer setpoint raise / Mop raise
p1036[0...n]
BI: Motorized potentiometer lower setpoint / Mop lower
p1055[0...n]
BI: Jog bit 0 / Jog bit 0
p1056[0...n]
BI: Jog bit 1 / Jog bit 1
p1070[0...n]
CI: Main setpoint / Main setpoint
p1113[0...n]
BI: Setpoint inversion / Setp inv
p1140[0...n]
BI: Enable ramp-function generator/inhibit ramp-function generator / RFG enable
p1141[0...n]
BI: Continue ramp-function generator/freeze ramp-function generator / Continue RFG
p1142[0...n]
BI: Enable setpoint/inhibit setpoint / Setpoint enable
p1500[0...n]
Macro Connector Inputs (CI) for torque setpoints / Macro CI M_set
p2103[0...n]
BI: 1. Acknowledge faults / 1. Acknowledge
p2104[0...n]
BI: 2. Acknowledge faults / 2. Acknowledge
p2105[0...n]
BI: 3. Acknowledge faults / 3. Acknowledge
p2106[0...n]
BI: External fault 1 / External fault 1
p2107[0...n]
BI: External fault 2 / External fault 2
p2108[0...n]
BI: External fault 3 / External fault 3
p2112[0...n]
BI: External alarm 1 / External alarm 1
p2116[0...n]
BI: External alarm 2 / External alarm 2
p2117[0...n]
BI: External alarm 3 / External alarm 3
p2200[0...n]
BI: Technology controller enable / Tec_ctrl enable
p2253[0...n]
CI: Technology controller setpoint 1 / Tec_ctrl setp 1
p2254[0...n]
CI: Technology controller setpoint 2 / Tec_ctrl setp 2
p2264[0...n]
CI: Technology controller actual value / Tec_ctrl act val
p2286[0...n]
BI: Hold technology controller integrator / Tec_ctr integ hold
p2289[0...n]
CI: Technology controller pre-control signal / Tec_ctr prectr_sig
p2296[0...n]
CI: Technology controller output scaling / Tec_ctrl outp scal
p2297[0...n]
CI: Technology controller maximum limit signal source / Tec_ctrMaxLimS_src
Note:
References:
SINAMICS DC MASTER operating instructions
“Data sets” Chapter
Summary of Contents for SINAMICS DCM
Page 1: ...s SINAMICS SINAMICS DCM List Manual 02 2015 Edition Answers for industry ...
Page 2: ......
Page 1192: ...A Appendix A 2 List of abbreviations SINAMICS DCM 1192 List Manual LH8 02 2015 6RX1800 0ED76 ...
Page 1202: ...Index SINAMICS DCM 1202 List Manual LH8 02 2015 6RX1800 0ED76 ...
Page 1203: ......