2 Parameters
2.3 Parameters for data sets
SINAMICS DCM
652
List Manual (LH8), 02/2015, 6RX1800-0ED76
p50402[0...n]
Fixed value 2 / Fix val 2
p50403[0...n]
Fixed value 3 / Fix val 3
p50404[0...n]
Fixed value 4 / Fix val 4
p50405[0...n]
Fixed value 5 / Fix val 5
p50406[0...n]
Fixed value 6 / Fix val 6
p50407[0...n]
Fixed value 7 / Fix val 7
p50408[0...n]
Fixed value 8 / Fix val 8
p50409[0...n]
Fixed value 9 / Fix val 9
p50410[0...n]
Fixed value 10 / Fix val 10
p50411[0...n]
Fixed value 11 / Fix val 11
p50412[0...n]
Fixed value 12 / Fix val 12
p50413[0...n]
Fixed value 13 / Fix val 13
p50414[0...n]
Fixed value 14 / Fix val 14
p50415[0...n]
Fixed value 15 / Fix val 15
p50416[0...n]
Fixed value 16 / Fix val 16
p50421[0...n]
Fixed bit 0 / Fixed bit 0
p50422[0...n]
Fixed bit 1 / Fixed bit 1
p50423[0...n]
Fixed bit 2 / Fixed bit 2
p50424[0...n]
Fixed bit 3 / Fixed bit 3
p50425[0...n]
Fixed bit 4 / Fixed bit 4
p50426[0...n]
Fixed bit 5 / Fixed bit 5
p50427[0...n]
Fixed bit 6 / Fixed bit 6
p50428[0...n]
Fixed bit 7 / Fixed bit 7
p50460[0...n]
Motorized potentiometer activate ramp-function generator / Mot pot act RFG
p50462[0...n]
Motorized potentiometer ramp-up time / MotP t_r-up
p50463[0...n]
Motorized potentiometer ramp-down time / MotP t_r-dn
p50464[0...n]
Motorized potentiometer time difference for dy/dt / MotP t_dif dy/dt
p50465[0...n]
Motorized potentiometer expansion factor / MotP exp fact
p50467[0...n]
Motorized potentiometer starting value / MotP start value
p50468[0...n]
Motorized potentiometer maximum speed / MotP n_max
p50469[0...n]
Motorized potentiometer minimum speed / MotP n_min
p50473[0...n]
Motorized potentiometer save output value / MotP save outp val
p50480[0...n]
Oscillation setpoint 1 / Oscillation set 1
p50481[0...n]
Oscillation setpoint 1 time / Oscill set 1 t
p50482[0...n]
Oscillation setpoint 2 / Oscillation set 2
p50483[0...n]
Oscillation setpoint 2 time / Oscill set 2 t
p50491[0...n]
Motor interface alarm threshold for temperature monitoring / Mot_temp al thr
p50492[0...n]
Motor interface fault threshold for temperature monitoring / Mot_temp flt thr
p50503[0...n]
Torque limiting t_set factor in slave mode / T_set fact sl mode
p50512[0...n]
Speed limiting controller max speed pos direction of rotation / n_max pos dir rot
p50513[0...n]
Speed limiting controller max speed neg direction of rotation / n_max neg dir
p50515[0...n]
Speed limiting controller P gain / n_lim Kp
p50520[0...n]
Friction compensation 0 % speed / Fric comp n 0%
p50521[0...n]
Friction compensation 10 % speed / Fric comp n 10%
p50522[0...n]
Friction compensation 20 % speed / Fric comp n 20%
p50523[0...n]
Friction compensation 30 % speed / Fric comp n 30%
p50524[0...n]
Friction compensation 40 % speed / Fric comp n 40%
p50525[0...n]
Friction compensation 50 % speed / Fric comp n 50%
p50526[0...n]
Friction compensation 60 % speed / Fric comp n 60%
p50527[0...n]
Friction compensation 70 % speed / Fric comp n 70%
p50528[0...n]
Friction compensation 80 % speed / Fric comp n 80%
p50529[0...n]
Friction compensation 90 % speed / Fric comp n 90%
p50530[0...n]
Friction compensation 100% speed / Fric comp n 100%
p50540[0...n]
Speed controller acceleration time / n_ctr t_accel
p50542[0...n]
RFG dy/dt time difference / RFG dy/dt t_dif