Advanced commissioning
6.8 Jogging
SINAMICS G115D distributed drive
Operating Instructions, 12/2020, FW V4.7 SP13, A5E48681219B-002
173
6.8
Jogging
The "JOG" function is typically used to temporarily move a machine part using local control
commands, e.g. a transport conveyor belt.
Commands "JOG 1" or "JOG 2" switch the motor on and off.
The commands are only active when the converter is in the "Ready for switching on" state.
After switching on, the motor accelerates to the setpoint JOG 1 or setpoint JOG 2. The two
different setpoints can, for example, be assigned to motor clockwise and counter-clockwise
rotation.
In JOG mode, the same ramp-function generator is active as for the ON/OFF1 command.
Parameters
Parameter
Description
Setting
p1120[0...n] Ramp-function generator,
ramp-up time [s]
Sets the ramp-up time for the ramp-function generator.
Factory setting: 1
p1121[0...n] Ramp-function generator,
ramp-down time [s]
Sets the ramp-down time for the ramp-function generator.
Factory setting: 1
p1058[0...n] Jog 1 speed setpoint [rpm] Sets the speed for JOG 1.
Factory setting: 150
p1059[0...n] Jog 2 speed setpoint [rpm] Sets the speed for JOG 2.
Factory setting: -150
p1082[0...n] Maximum speed [rpm]
Sets the highest speed.
Factory setting: 1500